Polling Commands & Messages:
As defined above, Status-Message are sent automatically in response to Control-Write Commands, but system status may also be
determined at any time by polling, using these optional Control-Read Commands. Applications that parse and process Status-
Messages in real-time will not need these Commands, but applications can ignore Messages until periodic polling intervals, and then
issue Polling Commands to update variables and displays.
Control-Read Cmd Description
Read-Zone-Audio-Status
Read-Zone-Video-Status
Read-Zone-Audio/Video-Status
Read-Zone-Audio/Video-Sources
Read-Zone-Audio-Source
Read-Zone-Video-Source
Read-Zone-Volumes
Read-Zone-Bass/Treble
Read-Group-All-Current
Read-Group-Audio-States
Read-Group-Video-States
Read-Group-Audio-Sources (note 1)
Read-Group-Video-Sources (note 1)
Read-Group-Left-Volumes
Read-Group-Right-Volumes (note 1)
Read-Group-Bass-Levels
Read-Group-Treble-Levels
Read-System-Information (note 2, 3)
Read-Acknowledge
zon is zone
bzn is Base-Zone for switcher
gbz is group-base-zone
sta is audio-state code
stv is video-state code
ssa is audio source
ssv is video source
vvl is left volume level
vvr is right volume level
bas is bass level
trb is treble level
fam,fid is Family,Family-ID
svh,svl is Software-Version-High,Low
Command
*CR,1,zon <cr>
*CR,2,zon <cr>
*CR,3,zon <cr>
*CR,10,zon <cr>
*CR,11,zon <cr>
*CR,12,zon <cr>
*CR,20,zon <cr>
*CR,40,zon <cr>
(note 1)
*CR,80,gbz <cr>
(note 1)
*CR,81,gbz <cr>
(note 1)
*CR,82,gbz <cr>
*CR,83,gbz <cr>
*CR,84,gbz <cr>
(note 1)
*CR,85,gbz <cr>
*CR,86,gbz <cr>
(note 1)
*CR,87,gbz <cr>
(note 1)
*CR,88,gbz <cr>
*CR,100,bzn <cr>
(note 2, 4)
*CR,101,bzn <cr>
1 to 255
1 to 249 for 8-zone, or 1 to 241 for 16-zone switcher (eg: 1, 9, 17...)
1 to 249; on 8-zone increments (eg: 1, 9, 17... ) (see note 1)
0=off, 1=on, 2=on/muted-audio
0=off, 1=on
0 to 8 (0=off)
0 to 8 (0=off)
0 to 35 (2-dB/increment)
0 to 35 (2-dB/increment)
0 to 8 (3-dB/increment)
0 to 8 (3-dB/increment)
10,5 = LE800A; 10,6 = LE800AV; 10,7 = LE1600A; 10,8 = LE1600V
(0 to 99 each, eg: 6,0 is version 6.0)
Status-Message
!S,1,zon,sta,ssa,vvl,vvr,bas,trb <cr>
!S,2,zon,stv,ssv <cr>
!S,3,zon,sta,stv,ssa,ssv,vvl,vvr,bas,trb <cr>
!S,10,zon,ssa,ssv <cr>
!S,11,zon,ssa <cr>
!S,12,zon,ssv <cr>
!S,20,zon,sta,vvl,vvr <cr>
!S,40,zon,bas,trb <cr>
!S,81... through !S,88...
!S,81,bzn,sta1,sta2...sta8 <cr>
!S,82,bzn,stvl1,stv2...stv8 <cr>
!S,83,bzn,ssa1,ssa2...ssa8 <cr>
!S,84,bzn,ssv1,ssv2...ssv8 <cr>
!S,85,bzn,vvl1,vvl2...vvl8 <cr>
!S,86,bzn,vvr1,vvr2...vvr8 <cr>
!S,87,bzn,bas1,bas2...bas8 <cr>
!S,88,bzn,trb1,trb2...trb8 <cr>
!S,100,bzn,fam,fid,0,0,svh,svl <cr>
!S,101,bzn <cr>
(or 0 to 16, for 16-source switchers)
(or 0 to 16, for 16-source switchers)
21