Advertisement

Quick Links

2040RDA-FR/16FR
FIBER READY DISTRIBUTION AMPLIFIERS
Instruction Manual
SOFTWARE VERSION 2.0.0
071836000
DECEMBER 2004

Advertisement

Table of Contents
loading

Summary of Contents for GRASS VALLEY 2040RDA-FR/16FR

  • Page 1 2040RDA-FR/16FR FIBER READY DISTRIBUTION AMPLIFIERS Instruction Manual SOFTWARE VERSION 2.0.0 071836000 DECEMBER 2004...
  • Page 2 Germany, Europe +49 6150 104 782 +49 6150 104 223 Copyright © Thomson Broadcast and Media Solutions All rights reserved. Grass Valley Web Site www.thomsongrassvalley.com web site offers the following: — Current versions of product catalogs, brochures, Online User Documentation data sheets, ordering guides, planning guides, manuals, and release notes in .pdf format can be downloaded.
  • Page 3: Table Of Contents

    ..............2040RDA-FR/16FR Instruction Manual...
  • Page 4 Contents 2040RDA-FR/16FR Instruction Manual...
  • Page 5: Preface

    This manual describes the features of a specific 2000 Series module in the Kameleon Media Processing System. As part of this module family, it is subject to Safety and Regulatory Compliance described in the 2000 Series frame and power supply documentation (see the Kameleon 2000 Series Frames Instruction Manual). 2040RDA-FR/16FR Instruction Manual...
  • Page 6 Preface 2040RDA-FR/16FR Instruction Manual...
  • Page 7: 2040Rda-Fr, 2040Rda-16Fr Fiber Ready Distribution Amplifiers

    • Reclocks at 143 Mb/s, 177 Mb/s, 270 Mb/s, 360 Mb/s, 540 Mb/s, or 1485 Mb/s, • Distributes transport streams in bypass mode, • Auto-adjust rise/fall times to meet either the SD or HD standard, and • Supports networked control and monitoring in frames with 2000NET module. 2040RDA-FR/16FR Instruction Manual...
  • Page 8: Installation

    When the jumper is placed across pins 1 and 2 of jumper block JP1, module settings are changed from the on-board jumpers only; remote control is locked out. To have both Local and Remote access, set the jumper across pins 2 and 3. 2040RDA-FR/16FR Instruction Manual...
  • Page 9 Jumper across pins 2–3 to enable remote and local control. Input Select Set JP2 and JP3 for input according to module silkscreen. Auto/Bypass Reclocking Jumper across pins 1–2 selects automatic reclocking. Jumper across pins 2–3 bypasses reclocking function. 2040RDA-FR/16FR Instruction Manual...
  • Page 10: Input/Output Select Jumpers

    Set jumper JP4 for auto-reclocking (AUTO pins 1-2) or to bypass reclocking (BPSS pins 2-3). This jumper setting can be overridden by remote control. When the module is in Bypass, the front edge LD LED will be off (refer to Table 1 on page 21). 2040RDA-FR/16FR Instruction Manual...
  • Page 11: Module Placement In The 2000 Frame

    Figure 3. 2040RDA-FR 3 RU Frame, Rear View Mid-frame motherboard with power and communication buses 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA 2040RDA Rear media module slots 7– 12 Rear media module slots 1– 6 2040RDA-FR/16FR Instruction Manual...
  • Page 12 1. Locate a vacant slot in slot 1-12 in the rear of the 1 RU or 3 RU frame (3 RU frame shown in Figure 2. Insert the rear module into a vacant rear slot in the frame as illustrated Figure 2040RDA-FR/16FR Instruction Manual...
  • Page 13 To continue installation of 2040RDA-FR and 2040RDA-16FR modules set in the frame: 1. Verify that the module connector seats properly against the midplane. 2. Using a crossblade screwdriver, tighten the two screw locks to secure the module in the frame. 2040RDA-FR/16FR Instruction Manual...
  • Page 14 BNCs. Do not try to force it in further. Figure 7. Installing SFP Submodule on 2040RDA-FR 2040RDA Arrow Indicators Handle in up position Label Figure 8. Installing SFP Submodule on 2040RDA-16FR Label Arrow Indicators Handle in up position 2040RDA-FR/16FR Instruction Manual...
  • Page 15 Figure 10. 2000 Series 3 RU Frame, Front Slots (10) (11) (12) Install Front Media modules into slots 1, 3, 5, 7, 9, and 11. 2040RDA-FR/16FR Instruction Manual...
  • Page 16 9. Verify that the module connector seats properly against the midplane and rear module connector. 10. Press firmly on both ejector tabs to seat the module. Figure 11. Installing Front Media Module 2000 Frame (front view) Alignment post and receptacle Board edge Board edge guides guides 2040RDA-16FR 2040RDA-FR/16FR Instruction Manual...
  • Page 17: Cabling

    Figure 12. 2040RDA-FR Rear Module Input/Output Connectors SFP Submodule Input Outputs BNC J1, J3-J9 connector cage 2040RDA Figure 13. 2040RDA-16FR Rear Module Input/Output Connectors SFP Submodule connector cage Outputs J1 – J8 2040 RDA-16 Input Outputs J9 – J16 2040RDA-FR/16FR Instruction Manual...
  • Page 18 17). On the 2040RDA-16FR the input signal is distributed to 16 output BNCs. Connect video output devices to outputs J1 through J8 and J9 through J16 provided on the 2040RDA-16FR rear module (Figure 13 on page 17). 2040RDA-FR/16FR Instruction Manual...
  • Page 19: 2040Rda-Fr Or 2040Rda-16Fr With Dual Optical Transmitter

    Input/Output Select Jumpers on page 10. With the submodule handle in the up position, connect optical cables to one or both outputs. Figure 14. Dual Transmitter Optical Outputs Optic 1 (output) Optic 2 (output) 2040RDA-FR/16FR Instruction Manual...
  • Page 20: 2040Rda-Fr Or 2040Rda-16Fr With Optical Transceiver

    Input/Output Select Jumpers on page 10. With the submodule handle in the up position, connect an optical cable to this output. Figure 15. Dual Transceiver Optical Input and Output Optic 1 (output) Optic 2 (input) 2040RDA-FR/16FR Instruction Manual...
  • Page 21: Power Up

    No power to module, fuse blown, or module’s DC/DC converter failed. (green) On continuously Normal operation, module is powered. Remote control is overriding on-board jumper settings. REM OVR (yellow) Module is operating according to on-board jumper settings. 2040RDA-FR/16FR Instruction Manual...
  • Page 22 Table 2. Reclock Mode Table Mode LED 1 Mode LED 2 Mode LED 3 Reclock Rate (DS4) (DS5) (DS6) No reclock 143M 177M 270M 360M 540M 1.5 G 2040RDA-FR/16FR Instruction Manual...
  • Page 23: Configuration And Adjustments

    TRL Transceiver Select Input Current JP3 Settings/ JP2: N/A (Tx-Rx 1310NM jumper setting Optic 2 or Coax InSelTR Input pulldown JP3: 0 = Optic 2 Input Select installed) Factory = Coax JP3: 1 = Coax Input Select 2040RDA-FR/16FR Instruction Manual...
  • Page 24: Newton Control Panel Configuration

    The available control panel controls for the module are listed Table 3 on page An example of the Newton Configurator is shown in Figure Figure 17. Newton Configurator Example Refer to the documentation that accompanies the Newton Modular Control System for installation, configuration, and operation information. 2040RDA-FR/16FR Instruction Manual...
  • Page 25: Web Browser Interface

    2000NET module software. They are provided for reference only. Displays will differ depending on the type of platform and browser you are using and the version of the 2000NET software installed in your system. This manual reflects 2000NET software version 3.2.2. 2040RDA-FR/16FR Instruction Manual...
  • Page 26 Content display section displays the information page for the selected frame or module (frame slot icons are also active links). Refresh button for manual update of page 2040RDA-FR/16FR Instruction Manual...
  • Page 27: 2040Rda-16Fr Links And Web Pages

    Figure 19. 2040RDA-FR or 2040RDA-16FR Web Page Links Note The web pages for the 2040RDA-FR are identical to the ones shown in this manual except for the Model name in the heading (2040RDA-FR) or where otherwise indicated. 2040RDA-FR/16FR Instruction Manual...
  • Page 28: Status Web Page

    Information about the module, such as part number, serial number, hard- ware revision and software and firmware versions are given in a read-only section at the bottom of the display. Properties Figure 20. 2040RDA-FR Status Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 29 Configuration and Adjustments Figure 21. 2040RDA-16FR Status Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 30: Settings Web Page

    Reclk 540M – set the module to lock to a specific reclock rate. If the Reclk 1485M signal cannot lock to the selected rate, the output will be invalid. Figure 22. Coax settings Web Page (No SPF Module) 2040RDA-FR/16FR Instruction Manual...
  • Page 31 (not available or enabled). Present Not Present • – reports whether the signal is Reclocker: Locked Unlocked • – reports the bit rate currently detected ( Auto Rate: 143M 177M 270M 360M , or , or 540M 1485M Unknown 2040RDA-FR/16FR Instruction Manual...
  • Page 32 • – enable or disable the Optic 1 output with the pulldown. Optic 1 TX • – enable or disable the Optic 2 output with the pulldown. Optic 2 TX Figure 23. Dual Transmitter Settings Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 33 • – select the as the input with the pulldown. Input Coax Optic 2 • – enable or disable the output with the pulldown. Optic 1 Tx Optic 1 Figure 24. Transceiver Settings Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 34: Recall Factory Defaults Web Page

    The module will return to the current onboard jumper settings as the factory defaults. Be sure to set these jumpers as desired during installation. Refer to Factory Defaults on page Figure 25. Recall Factory Defaults Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 35: Slot Config Web Page

    The enabled SNMP traps will be reported to any SNMP manager that is identified as an SNMP Report Destination in 2000NET configuration. Trap severity is read-only hard-coded information that is interpreted and responded to by the SNMP Manager software configuration. 2040RDA-FR/16FR Instruction Manual...
  • Page 36 Configuration and Adjustments Figure 26. Slot Config Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 37: Software Update Web Page

    files and a serial cable assembly available from Grass Valley. Refer to the 8900-FLOAD-CBL Software Upgrade Instruction Manual in pdf format on the CD-ROM for complete updating instructions and the required software files for the 2040RDA-FR or 2040RDA-16FR. Figure 27. Software Update Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 38: Rear Module Web Page

    If no rear module is present or the wrong rear module is installed, the front this edge FAULT LED will light as described in Table 1 on page link Figure 28. Rear Module Web Page 2040RDA-FR/16FR Instruction Manual...
  • Page 39: Specifications

    >15 dB 0.004 to 540 MHz, >10 dB from 540 MHz to 1.5 GHz Signal level 800 mV p-p ± 10% maximum Rise and fall time < 270 ps for reclocked HD (20-80%) 400-800 ps for SD and Bypass mode 2040RDA-FR/16FR Instruction Manual...
  • Page 40 2000T3 – 12 module sets per frame, no special restrictions for 2040RDA-FR 2000T1 – 4 modules sets per frame, no special restrictions for 2040RDA-FR 2000T3 – 6 module sets per frame, no special restrictions for 2040RDA-16FR 2000T1 – 2 modules sets per frame, no special restrictions for 2040RDA-16FR 2040RDA-FR/16FR Instruction Manual...
  • Page 41: Service

    The 2040RDA-FR and 2040RDA-16FR modules make extensive use of sur- face-mount technology and programmed parts to achieve compact size and adherence to demanding technical specifications. Circuit modules should not be serviced in the field unless as directed by Grass Valley Cus- tomer Service. Power-up Diagnostics Failure If the module has not passed self-diagnostics, do not attempt to trouble- shoot.
  • Page 42: Module Repair

    Module Repair If the module is still not operating correctly, replace it with a known good spare and return the faulty module to a designated Grass Valley repair depot. Call your Grass Valley representative for depot location. Refer to Contacting Grass Valley at the front of this document for the Grass Valley Customer Service Information number.
  • Page 43: Electrical Input And Output Processing

    The output amplifiers drive 8 equal-phase outputs on the passive rear module (BNCs J1,J3-J9) on the 2040RDA-FR or 16 equal-phase outputs on the passive rear module (BNCs J1 – J16) on the 2040RDA-16FR. 2040RDA-FR/16FR Instruction Manual...
  • Page 44: Optical Input And Output Processing

    Using this information, local jumper set- tings, and remote control commands, the microprocessor selects the internal signal path and gives feedback through the LEDs and remote control bus. 2040RDA-FR/16FR Instruction Manual...
  • Page 45: Index

    (coax) installation electrical outputs (coax) optical input (Rx) fuse optical outputs (Tx) location and type CD LED circuit descriptions Coax (no submodule) Grass Valley web site cabling settings COMM LED configuration summary control panel input cabling specification input signal name...
  • Page 46 Slot Config web page overview SNMP reporting enabling software download from web Software Update web page online documentation Status web page operational modes submodule Optical Transceiver submodule installation cabling local control settings remote control settings 2040RDA-FR/16FR Instruction Manual...
  • Page 47 Index testpoints troubleshooting video input electrical (coax) optical video outputs electrical (coax) optical web browser overview web site documentation FAQ database Grass Valley software download 2040RDA-FR/16FR Instruction Manual...
  • Page 48 Index 2040RDA-FR/16FR Instruction Manual...

Table of Contents