Intended Use; Forseeable Misuse; Residual Risks; Technical Data - unicraft KW 50 Operating Instructions Manual

Crane scale
Table of Contents

Advertisement

3

Intended use

The Crane scale is used solely to weigh free moving
loads on the crane. The Crane scale may only be opera-
ted by persons trained on the machine.
Proper use also includes compliance with all information
in this manual. Any use beyond the intended use or
otherwise is considered misuse.
For structural and technical changes to the Crane scale,
the company Stürmer Maschinen GmbH assumes no lia-
bility.
Claims of any kind due to damage due to improper use
are excluded.
3.1 Foreseeable misuse
If the intended use is observed, any reasonably foresee-
able misuse which could lead to hazardous situations
with personal damage is impossible with the crane
scales.

3.2 Residual risks

Even if all safety regulations are observed a residual risk
in the operation of the crane scales will remain, as de-
scribed below.
All persons working with the crane scales must be aware
of these residual risks and follow the instructions which
prevent any accidents or damage caused by these resi-
dual risks.
- Risk of crushing of upper and lower limbs while
equipment is operating.
- During set-up and adjustment works it may be-
come necessary to remove safety devices in-stal-
led by the customer. This causes different re-sidual
risks and hazard potentials each operator must be
aware of.
KW-Series | Version 1.03
4

Technical Data

KW
KW 50
Maximum load
5000
[kg]
Display
30 mm,
5 digit LED/
LCD
Display-
<2000kg = 1kg
gradation
5000kg = 2kg
Tare
100 % the total capacity
Zero range
4 % the total capacity
stabilization
<10 sec.
time
Overload
100% of max. Capacity +9e (45 g)
indicator
max. secure
125% of max.
Load
Capacity
max. Overload
400% of max.
Capacity
Battery
re-chargable / 60-100h battery life
until next re-charge 6V (10Ah)
Charger
220 V / DC 9 V / 1500 mA
Range remote
10 m
control
Battery remote
AA Batteries,
control
1,5V x 2
Weight [kg]
25

4.1 Environmental conditions

Working tempera-
-10 °C to +40 °C
ture
Altitude
set up and use at a height of
max. 1000 m
Humidity
max. 90% relative humidity
working environ-
not flammable,
ment
dry and dust-free
Intended use
KW 100
10000
38,1 mm,
5 digit LED/
LCD
<2000kg = 1kg
5000kg = 2kg
10000kg=10kg
<10 sec.
125% of max.
Capacity
400% of max.
Capacity
10 m
AA Batteries,
1,5V x 2
47
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kw 10061714056171410