User Settings - unicraft KW 50 Operating Instructions Manual

Crane scale
Table of Contents

Advertisement

Delete (all entries)
Step 1: If you press
then all weights will be deleted. When the Sym-
bol
lights up, it means that all weights
are cleared.
Switch unit of measure
Step 1: Press
or
you want to switch between "kg" and "lb".
Step 2: a) If the scale is set to "kg", then the symbol be-
comes
KG
the display
.
b) If the scale is set to "lb", then the symbol will
become
LB
on the display
ATTENTION!
The circuit is short-lived. The balance does not store a
unit, i.e., the system unit is not changed.
Tara-Modus
Step 1: Press
or
press
or
Tara-mode. The Display shows
that the user input is expected.
Step 2: Press
or
Weight input.
Step 3: Press
or
TARE
The Symbol
a) The balance should be in gross mode,
otherwise the symbol
played.
b) The weight must be greater than 0, other-
wise the symbol
d) The weight must not exceed 100% of the
max. Capacity, otherwise the symbol
will be displayed.
Resolution circuit
Step 1: Press
or
you can switch the resolution. The display shows
a new resolution.
High resolution provides greater accuracy with longer
measurement times and places greater demands on the
stability of the load. The scale is built according to legal
guidelines. The scale has the best (standard) resolution
at 2000 to 3000 divisions.
KW-Series | Version 1.03
or
and avctivate
and then press
, if
is displayed and flashes on
is displayed and flashes
.
in the gross mode then
, The balance is now in
0000
, it means
, than
or
for the
and enter the tare weight.
shine.
will be dis-
will be displayed.
and then press
,now
,
ATTENTION!
The resolution circuit changes the overload range of the
scale. For example, if a 3000 * 1kg resolution is changed
to 3000 * 0.5kg, then the overload is displayed at
3004.5kg (3000 + 9 * 0.5), while by default it is dis-
played at 3009kg (3000 + 9 * 1) becomes.
Step 3: The default resolution will be restored the next
time the balance is turned on or user settings are
made. If you want to use the changes later, then
save the new resolution in the user preference.
Battery status view
Step 1: Press
battery status view is loaded.
Step 2: The display shows the battery voltage, for ex-
U 6.38
ample

8.2 User settings

Step 1: Press
. The user setting mode is now on.
The display shows
Resolution
Step 1: Press
resolution.
Step 2: The display shows the resolution. For ex-
ample
Step 3: Press
change the resolution.
Step 4: Press
the changes before exiting.
Step 5: Press
changes before exiting.
"Automatic shutdown" function
Step 1: Press
tomatic shutdown". The display shows
means that the balance is switched off after 15
minutes.
Step 2: Press
change the time.
Step 3: Press
save the changes before exiting.
Step 4: Press
changes before exiting.
Operation
or
and then press
, it means 6.38 V.
or
and then press
.
or
, if you want to change the
, the resolution is set to 0.5.
or
and
, if you want to
or
, if you do not want to save
or
, if you want to save the
or
, if you want to edit the "au-
or
and
, if you want to
and
, if you do not want to
or
, if you want to save the
, the
or
, it
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kw 10061714056171410

Table of Contents