Troubleshooting

11 Troubleshooting
Disorder
No indication after switching on
Display flashes continuously.
Tare function does not work.
Display does not show [0] after
discharge
The Button
The button re-
mains pressed after being pressed
The operation is not performed after
the key is pressed.
The reading of the weight is not pos-
sible
When reading the weight, the error is
displayed
Battery does not charge
Remote control without function

12 Disposal, recycling of used devices

Please take care in your own interest and in the interest
of the environment that all component parts of the ma-
chine are only disposed of in the intended and permit-ted
way.
12.1 Decommissioning
Disused machines should be professionally taken out of
operation in order to avoid later misuse and endanger-
ing of the environment or personal safety.
Step 1: Eliminate all environmentally hazardous operat-
ing materials from the used device.
Step 2: If necessary, dismantle the devices into manage-
able and usable components and components.
Step 3: The device components and operating materials
must be routed to the appropriate disposal rou-
tes.
18
Possible cause
Battery defective or not charged
Battery voltage too low
Tare-Button defective
Tare set?
Warm-up time of the Crane scale too
short
1. Battery voltage too low
2. The Button
is defective
3. Power cord is defective
4. Keyboard is defective
1. The scale is not on
2. The button is defective
1. The load is moving
2. The "anti-movement" feature is
weak
3. Load cell or keyboard are wet
4. Keyboard is defective
1. The scale was not set to "0" before
the new load
2. Wrong unit
1. Pallet is defective
2. Battery is defective
1. Battery too weak
2. Distance too big
Solution
Charge or replace the battery
Charge or replace the battery
Clean or Crane scale for repair
1.Set tare
2. Longer warm-up time
1. Charge or replace the battery
2. Press harder and hold for approx.
2 sec
3. Open the front panel and check
the power cord
4. Contact dealer
1. Reconnect the power cord
2. Contact dealer
1. Keep the load stable
2. Take higher "anti-movement" level
3. Take higher "anti-movement" level
4. Contact dealer
1. Manually set the scale to "0"
2. Switch to the correct unit
1. Contact dealer
1. Change the battery
2. Reduce distance