9. Installation
Service Manual

8.6 Drain Water

TDrain pan and drain hose need to be installed before using. Drain hose is
not included in the products, you need to purchase it locally to satisfy your
particular needs. Use the following procedure to install drain pan and drain
hose.
1. Slide out the chassis from the cabinet.
2. Install the drain pan to the corner of the cabinet with 2 screws.
3. Connect the drain hose to the outlet on the drain pan bottom.
4. Slide the chassis into its original place in the cabinet.
Note:
To get the maximum cooling efficiency , the air conditioner is designed to
splash the condensation water on the condenser coil . If the splashing sound
annoy you , you can remove the rubber plug from the chassis to lower the
noise, which also cause a bit loss of performance.

8.7 Notes for Installation

1) Remove
Before removing air conditioner to the other place, you shouldcontact the seller firstly.
Then it must be done under the direction of the professionaltechnician. In addition, t
he charge of this must be paid.
2) Noise
● Install in a location where is firm enough to avoid the enlargement of noise and vibration.
● Dont put anything in front of the outlet of outdoor unit to avoid increasing noise.
● Be sure that hot air or noise will not inconvenience r neighbors.
● Please contact the seller as soon as there is strange noise during operation.
● Please use the safety support.
3) Electric wiring
● Must connect with ground reliably.
● The exclusive circuit must be used. But removable socket cant be used because poor contact of it
can cause over heat or fire.
● Dont pull the power cord strongly.
● In fixed circuit, there must be electricity leakage protection switch and leakage current is less than 30mA.
● Connecting method between air conditioners and power cord and interconnecting method of each individual
element with one another should accord with wiring diagram on the unit.
● The air conditioner should be installed in accordance with national wiring regulation.
● An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
● Air switch (thermal-magnetic breaker) should be installed in the circuit If the supply cord is damaged,it must be replaced by the
manufacturer or your dealer or a qualified person to avoid a hazard.
● All The dectrical work must be done according to the local wiring regulations.