Troubleshooting By Symptom (Portable) - Panasonic KX-TG9471B Service Manual

Digital corded/cordless answering system
Hide thumbs Also See for KX-TG9471B:
Table of Contents

Advertisement

KX-TG9471B/KX-TG9472B/KX-TGA939T
9.3.

Troubleshooting by Symptom (Portable)

If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don't have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to Check Point (Portable) (P.44)
9.3.1.
Check Point (Portable)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*: How to install Batch file into P.C. (P.61) is required beforehand.
The connections of adjustment equipment are as shown in Adjustment Standard (Portable) (P.62).
Items
(A)* 1.8 V Supply Adjustment
(B)*
BBIC Confirmation
(C)* EEP-ROM Confirmation
(D) Charge Control Check &
Charge Current Monitor
Check
(E)* Charge Detection (OFF)
Check
Check
Point
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command "VDD", then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command "VDD XX"(XX is the
value).
-
1. BBIC Confirmation (Execute the command "getchk").
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
ex.)
-
1. EEP-ROM Confirmation (Execute the command "ChkTGA939XXrevYY.bat").
XX: country code
YY: revision number
2. Confirm the returned checksum value.
Note:
"XX", "YY", and "checksum" vary depending on the country version. You can find
them in the batch file.
-
1. Apply 3.5 V between CHG(+) and CHG(-) with DC power supply and set cur-
rent limit to 250 mA.
Confirm the indication of "charging" on LCD.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
Confirm it after waiting over 1 minute at least.
3. Decrease current limit of DC power supply to 100 mA.
4. Confirm that the current limit LED of DC power supply is stable. (Current limiter
is ON.)
(If charge control cannot be confirmed by this procedure, please use battery to porta-
ble power supply and try again.)
-
1. Stop supplying 3.5 V to CHG (+) and CHG (-).
2. Confirm the indication of "charging" has been cleared.
Procedure
checksum value
program number
EB48
DB02AA
44
Check or
Replace Parts
IC1, Q2, C48,
D1, C1, C44,
R12, C3, R45,
C40, C45, F1,
L8
IC1, X1, RA61,
R64, R66
IC1, IC3,
R40~R42,
C172
IC1, Q4 Q9,
D7, D8, L4, L5,
R6, R7, F1,
C1, C3, R2,
R30, R31, R8,
C147, R45,
C15, L8
IC1, Q4 Q9,
D7, D8, L4, L5,
R6, R7, F1,
C1, C3, R2,
R30, R31, R8,
C147, R45,
C15