Page 1
USER INSTRUCTIONS Retractable Fall Arrester PC. 915207, 915210, 915220, 915230 This equipment is intended for use by people who have received proper training and are competent. AS 1891.3:2020 (BMP No. 739186)
0.6m (600mm). • Self-Retracting Lanyard with Sharp Edge: Austlift 915207 and 915210 retractable lanyards with sharp edge (SE) are suitable for applications where the lifeline remains generally horizontal during use and possible free fall is limited to less than 1.5m.
Breaking distance less than 2 mtr 2. Dynamic Strength 100 Kg mass held a. Perpendicular to the edge b. Lateral offset of 1.5 mtr 3. Static Strength after each Dynamic f=3kN (Cable) 4.5 kN (Textile) 3 mints Strength test 915207...
SPECIFICATIONS UNIT: MM 915207 915210 915220 915230 INSPECTION BEFORE USE • Inspect the system thoroughly before use, ensure the locking mechanism is working correctly and the cable is retracting fully. • Ensure the cable is in good condition and free of any defects.
• Ensure that the strength of the anchor device is greater than 12kN or min 15kN single anchor point as per AS/NZS 5532 standard. • Use karabiner conforming to EN 362 with minimum gate strength of 6kn or ANSI for connecting to the anchor points. 915207...
Page 6
- the manufacturer shall be contacted. 2. The anchor point should only be situated at the same height as the edge at which a fall might occur or above the edge. 915207...
WARRANTY All AUSTLIFT products bear 1-year warranty against manufacturing defects, applicable on Unused AUSTLIFT products, from the date of purchase. However, AUSTLIFT shall not be liable for any accident or damage while the product is in use. LIFESPAN The estimated product lifespan of this product is 10 years from the date of manufacturing.
DISCLAIMER This information on the product is based upon technical data that AUSTLIFT obtained under laboratory conditions and believes to be reliable. AUSTLIFT does not guarantee results and takes no liability or obligation in connection with this information. As conditions of end use are beyond our control it is the user’s responsibility to determine the hazard levels and the use of proper...
Page 9
12. Do not use a unit laying flat on its side in a horizontal application, this may impede the way the wire or webbing coils back into the unit, preventing the unit from functioning correctly, special brackets are available for use in this application. 915207...
Need help?
Do you have a question about the 915207 and is the answer not in the manual?
Questions and answers