Download Print this page
Xylem WTW IDS SenTix ORP-T 900 Operation Manual

Xylem WTW IDS SenTix ORP-T 900 Operation Manual

Orp electrode
Hide thumbs Also See for WTW IDS SenTix ORP-T 900:

Advertisement

Quick Links

OPERATING MANUAL
OPERATION MANUAL
ba75845e04 06/2017
®
SenTix
ORP-T 900(-P)
®
SenTix
ORP-T 900(-P)
ORP ELECTRODE

Advertisement

loading

Summary of Contents for Xylem WTW IDS SenTix ORP-T 900

  • Page 1 OPERATING MANUAL OPERATION MANUAL ba75845e04 06/2017 ® SenTix ORP-T 900(-P) ® SenTix ORP-T 900(-P) ORP ELECTRODE...
  • Page 2 ® SenTix ORP-T 900 2017, Xylem Analytics Germany GmbH © Copyright Printed in Germany. ba75845e04 06/2017...
  • Page 3: General Information

    ® SenTix ORP-T 900(-P) General information General information Automatic sensor The sensor electronics with the stored sensor data are in the connecting recognition head of the electrode. The data include, among other things, the sensor type and series number. The data are recalled by the meter when the sensor is connected and are used for measurement and for measured value documen- tation.
  • Page 4 ® Commissioning, measuring, checking SenTix ORP-T 900(-P) Commissioning, measuring, checking Opening and closing the IDS plug connection ® This section only applies to variants with IDS plug (SenTix ... -P). Plug connection closed and locked Guidance Groove Opening the plug ...
  • Page 5 ® SenTix ORP-T 900(-P) Commissioning, measuring, checking Commissioning ® Scope of delivery  Electrode SenTix ORP-T 900(-P)  Operating manual Commissioning Prepare the electrode for measuring as follows:  Open the refilling opening for the reference electrolyte solution. Depend- ing on the model, the stopper of the refilling opening is an elastomer stop- per or a slider.
  • Page 6 ® Commissioning, measuring, checking SenTix ORP-T 900(-P)  Measure with the electrode according to the operating manual of the meter and observe the following rules while doing so: Measuring: General rules  Make sure the refilling opening for the reference electrolyte solution is open.
  • Page 7 ® SenTix ORP-T 900(-P) Storage is temperature dependent and can be taken from the following table (see also DIN 38404-6): T (°C) [mV] T (°C) [mV] ® ® SenTix ORP-T 900 SenTix ORP-T 900 +224 +200 +221 +196 +217 +192 +214 +188 +211...
  • Page 8: Maintenance And Cleaning

    ® Maintenance and cleaning SenTix ORP-T 900(-P)  High changes in pH and temperature. The warranty does not cover failure caused by measuring conditions and mechanical damage. Maintenance and cleaning During operation, a small amount of reference electrolyte leaks through the junction from the electrode into the test sample.
  • Page 9: Technical Data

    ® SenTix ORP-T 900(-P) Technical data Contamination Cleaning procedure Protein Immerse in pepsin cleaning solution PEP/pH for approx. 1 hour. Note: Make sure the level of the reference electro- lyte is above that of the cleaning solution. After cleaning Rinse the electrode with deionized water. Technical data Measurement and mV measuring range...
  • Page 10: Wear Parts And Accessories

    ® Wear parts and accessories SenTix ORP-T 900(-P) IDS plug Connection type 4-P-pin, watertight plug connection with locking device, reverse polarity protected Storage With watering cap; filled with KCl 3 mol/L, Ag free Wear parts and accessories Maintenance Description Model Order no.
  • Page 11 ® SenTix ORP-T 900(-P) Disposal General Description Model Order no. accessories ® Plastic armoring for SenTix ORP-T 900(-P) A pHLab/K 903 841 pH electrodes Disposal At the end of its operational lifetime, the electrode must be returned to the disposal or return system statutory in your country (electronic waste). If you have any questions, please contact your supplier.
  • Page 12 ® Disposal SenTix ORP-T 900(-P) ba75845d04 06/2017...
  • Page 14 Xylem also provides a leading portfolio of smart metering, network technologies and advanced analytics solutions for water, electric and gas utilities. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions.

This manual is also suitable for:

Wtw ids sentix orp-t 900-p