The operator of the system has the obligation to inform himself regarding the dangers which
may occur during usage, so that he/she can avoid them or minimize their occurrence as best
as he/she is able to.

4.Instrutions for installation

4.1 Installation

The machine is ready to work. Just place it to the requested position and connect it to
the power.
The good operation of the machine is depended of the feedwater formation.
Feedwater requirements:
Hardness
less than 100mg/las CaCO or less than 6 German degrees
PH
7-8
CO
No free CO allowed.
TDS
less than 200mg/l.
Fe
None
Suspended solids
Water should be clear and free from suspended solids, colloids, alcal, ect
In case that the hardness of the water is more than the above requirements, it is
recommended to use ANTISCAL. The lime contained in the water may be placed in the boiler
and on the heating elements will cause faults. The use of ANTISCAL prevents deposits of lime.

4.2 Electrical Connection

For the electrical connection and all for the power supply, please follow carefully the
instructions of the wiring diagram (enclosed) as well the WARNING symbols, attached to the
machine.Connect the machine to the power supply through the plug Nο 47 (see images of
the spare parts on page 13) . If power supply is 230Volt/1phase, the connection must be
done ,in a 3-poles socket plug (1 phase, 1 neutral, 1 ground). The power must be insured by a
2-poles (25 Amber) fuse.
CAUTION! For your own safety, pay attention to all the warning labels (yellow coloured) that
are placed on the machine. The manufacturer bears no liability for any damages or accidents
due to faulty supplying network or to not specified personnel.