7.Troubleshooting

7.1 The pump does not run:

 Check the red lamp (LED) responding to the pump, on the PC card typ.1098 or 0599,
which is next to the black micro relay of 30A. If the red lamp is on check the fuse 6
Amber responding to the pump on the PC card typ 1098 or 0599.
 Check if the voltage of the power supplied to the pump is 230V.
 Check if the pump is stuck off due to corrosion or salts.This usually happens when the
pump is out of work for a long period of time.
Shooting : Turn the Pivot of the pump by putting a
screwdriver though the hole of the backside of the
machine which leads to the pump.
 Check if the pump is blown-off. Replace it.
7.2 The water is not heated while the green lamp 1(steam) lights on.
 Check the red lamp (LED) which is used for the heating micro relay on the PC card
typ.1098 or 0599 No 36.
 If it is on, check the fuse 1 Amber which is used for the heating micro relay on the PC
card typ.1098 or 0599 No 36
 Check the micro relay 2x10 Amber which is used for the heating on the PC card
typ.1098 or 0599 No 36.
 If the red lamp (LED) responding to the heating micro relay is off check the pressostat
No 14 (symbol PS on the wiring diagram)
 Check the heating relay 3 x 25A , R1 (symbol on the wiring diagram)
 Check the overheating system.

7.3 The boiler is overheated. The overheating lamp (No 54) is on.

 Wait for a while, until the steam generator brings the temperature down.
 Unscrew the black knob towards left(No24).
 Inside, there is a small black buttom.(RESET)Press it. The overheating lamp is of.
The steam genarator is then ready to refunction. In case that even after the RESET proce-
dure the steam generator does not function, please
assistance.
Shooting:Clean up the steam generator and the electrodes from salts and replace the
electrodes if necessary.Check the water's level control system.Do the test for the good
operation of the machine.
7.4 The steam iron is not heated while the iron green lamp (on the keyboard) lights
on.
 Check the red lamp (LED) responding to the iron on the PC card typ 1098 or 0599. If it
is on check the fuse 6 Amber responding to the iron on the PC card typ 1098 or 0599
 Check the micro relay 2x10 Amber responding to the iron on the PC card 1098 or 0599
 Check the socket (PF1 or PF2 on the wiring diagram) where the iron is plugged.
Check the iron itself.
If the iron is heated normally but it does not blow steam check coil No 31 (12W/230V) of
the solenoid steam valves (V1, V2 on the wiring diagram)
7.5 The boiler is overfilled and the iron blows steam & water
 Check the electrodes No 46,47,48 :clean or replace them.
 Check the solenoid water valve No18 : clean or replace it.
 Check if the water's level control system on the PC card typ.1098 is running normally.