Rohs; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RS940GF Installation Manual

Rugged
Table of Contents

Advertisement

6.1.6

RoHS

This device is declared by Siemens AG to meet the requirements of the following
RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS940GF has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
RUGGEDCOM RS940GF
Installation Manual, 01/2021, C79000-G8976-1356-04
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
Description
Enclosure
Contact
Enclosure Air
Enclosure
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Earth
ground Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Signal Ports
D.C Power
Ports
AC Power
Ports
Earth
ground Ports
Enclosure
Ports
Certification
https://
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
± 4 kV line-to-earth,
± 2 kV line-to-line
± 2 kV line-to-earth,
± 1 kV line-to-line
± 4 kV line-to-earth,
± 2 kV line-to-line
10 V
10 V
10 V
10 V
40 A/m continuous,
1000 A/m for 1 s
6.1.6 RoHS
Severity
Levels
4
4
x
x
4
4
4
4
3
4
3
3
3
3
 
33

Advertisement