Page 3
Dear Customer, Thank you for choosing an AERMEC product. This product is the result of many years of experience and in-depth engineering research, and it is built using top quality materials and advanced technologies. In addition, the CE mark guarantees that our appliances fully comply with the requirements of the European Machinery Directive in terms of safety.
General warnings ................5 Receipt and handling ................ 6 Dimensions ..................7 Main hydraulic circuit ..............11 System loading ................13 System emptying ................13 System draining ................13 Percentage weight distribution on supports ........14 Electric connections ................ 16 Auxiliary connections(for standard version) ........
All the staff involved must have thorough knowledge of the operations and any dangers that may arise at the moment in which the installation operations are carried out. AERMEC will not assume any responsibility for damage due to failure to follow these instructions. PRODUCT IDENTIFICATION...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM RECEIPT AND HANDLING LIFT THE UNIT • The machine is delivered from the factory wrapped in estincoil. • Before handling the unit, verify the lifting capacity of the machines used. •...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM DIMENSIONS WITHOUT PUMPS DIMENSIONS (mm) PUNTI DI SOLLEVAMENTO (mm) LIFTING POINTS (mm) 83.46 in 2120 mm 2.95 in 75 mm 58.66 in 355 mm 1490 mm 755 mm 102.36 in 13.98 in 29.72 in...
Page 8
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM WITH PUMPS DIMENSIONS (mm) LIFTING POINTS (mm) 2120 mm 83.46 mm 320 mm 1202 mm 47.32 in 1202 mm 47.32 in 320 mm 405mm 12.60 in 12.60 in 15.94 in 3450 mm 135.83 in...
Page 9
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM WITH PUMPS DIMENSIONS (mm) LIFTING POINTS (mm) 2120 mm 83.46 mm 51.97 in 350 mm 1320 mm 51.97 in 1320 mm 350 mm 410 mm 13.78 in 3750 13.78 in 16.14 in 3750 mm 135.83 in...
Page 10
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM Model NXP_0500_0750[° - L] Model NXP_0800_1650[°] Model NXP_0500_0750[° - L] EV = Exchanger side (hot/cold) RC = Exchanger side (DHW) CN = Exchanger side (geothermal) Hydraulic Connection (Victaulic) Ø 3” (88,9mm) Ø...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM MAIN HYDRAULIC CIRCUIT MAIN HYDRAUL IC CIRCUITS ATTENTION Model: NXP WITHOUT PUMPS The choice and installation of compo- ............nents outside the units is the installer's INTERNAL HYDRAULIC CIRCUIT HYDRAULIC COMPONENTS...
Page 12
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM MAIN HYDRAUL IC CIRCUITS ATTENTION NXP WITH PUMPS Model: The choice and installation of compo- ............nents outside the units is the installer's INTERNAL HYDRAULIC CIRCUIT HYDRAULIC COMPONENTS responsibility, who must operate ac-...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM SYSTEM LOADING SYSTEM LOADING SYSTEM EMPTYING SYSTEM EMPTYING SYSTEM DRAINING SYSTEM DRAINING Before starting loading, position the unit master switch Before beginning emptying, place the unit master ATTENTION at OFF switch at OFF.
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM PERCENTAGE WEIGHT DISTRIBUTION ON SUPPORTS TOP VIEW VISTA SUPERIORE Electrical box Scatola elettrica (a sbalzo) Weight distribution percentage on supports unit operating Barycentre Weight Type KIT AVX Size (lbs) Xg (in)
Page 15
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM VISTA SUPERIORE TOP VIEW Electrical box Scatola elettrica (a sbalzo) Weight distribution Barycentre weight percentage on supports unit operating (%) Type KIT AVX Size (lbs) Xg (in) Yg (in) 0500 max 2 pumps 3,262.8...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM ELECTRIC CONNECTIONS ELECTRIC CONNECTIONS The units are completely wired at the factory and only THE FOLLOWING ARE MANDATORY The features of the electrical lines and of the related require connecti on to the electrical mains, downstream...
I/ O prog. on/o alar m enter Telephone cable S90CONN*: cavo di collegame nto Field-Bus RS485P1 serial board (ACCESSORY) For more informati on, refer to the wiring diagrams in the selecti on program or site www.aermec.com 21.05 - 6068956_00...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM USER INTERFACE(PGD1) User interface (pGD1) The NRP unit control panel allows quick se� ng of the machine functi oning parameters and their INTERFACE CONTROL KEYS display. Control keys Control keys The display is made up from a graphical matrix...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM Displays - Switching Unit on DISPLAYS - SWICHTING UNIT ON The following table shows the windows visible for the user when the unit is powered. Displays - Switching Unit on Unit display...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM MENU STRUCTURE AND NAVIGATION Menu structure and navigati on Menu display is organised by rotati on of the icons representi ng them. Having selected the desired icon, you enter the chosen menu, allowing you to view or modify the parameters making it up.
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM ASSISTANCE MENU(PROTECTED BY PASSWORD) Assistance Menu (protected by password) ASSISTANCE MENU MAIN SCREEN (parameters can be modifi ed by authorised personnel alone) Assistance Menu protected by password ASSISTANCE MENU MAIN SCREEN (parameters can be modifi...
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM USER OPERATIONAL PROCEDURES Use operati onal procedures To manage or modify the NRP unit operati onal parameters, the control board interface on the machine must be used. The fundamental operati ons that the user must be able to perform for correct use of the unit are: (1) To pass from one menu to another;...
(mandatory - That in models with three-phase power supply, the ries can be started up by the AERMEC A� er-Sales Service component for warranty to be valid). compressor noise level is not abnormal. If this is the in your area (valid only on Italian territory).
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM ROUTINE MAINTENANCE ROUTINE MAINTENANCE ELECTRIC CIRCUIT MECHANICAL CHECKS CHECK: CHECK: The tightening of the screws, the compressors Safety device efficiency. All cleaning is prohibited until the unit has been discon- The electric power supply voltage.
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM TROUBLE SHOOTING TROUBLE SHOOTING ANOMALY CAUSE REMEDY • Check the presence of voltage • No electric voltage • Check the safety systems upstream from the appli- ance • Master switch at OFF •...
Page 26
NXP 0500 - 1650 2-PIPE SYSTEM / 4-PIPE SYSTEM Power Supply: ELECTRIC DATA TABLE The cable sections shown in the table are recommended for maximum lengths of 50 m. For longer lengths or different cable laying, it is up to the DESIGN ENGINEER to...
Page 28
Via Roma, 996 37040 Bevilacqua (VR) - Italia Tel. + 39 0442 633111 Fax +39 0442 93577 marketing@aermec.com www.aermec.com Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.