Daikin FXFSQ-AVM Engineering Data page 34

Ceiling mounted cassette type (round flow with sensing) 50 / 60 hz
Table of Contents

Advertisement

FXFSQ-AVM
Item
Fresh white
Standard panel with
sensing sensor
Black
Fresh white
Standard panel 
Black
Designer panel
Fresh white
(Note 1) 
Auto grille panel
Fresh white
(Note 2,3) 
For usage of 3-, 4-way
Sealing material of
flow
air discharge outlet
For usage of 2-way
(Note 4)
flow
Panel spacer
Chamber
type
(Note
Fresh air intake kit
5,6,8)
Direct installation type
(Note 7)
(Colormetric method
High efficiency filter
65%)
unit (Including filter
chamber)
(Colormetric method
(Note 9)
90%)
(Colormetric method
Replacement high
65%)
efficiency filter
(Colormetric method
(Note 9,10)
90%)
Filter chamber
Replacement long-life filter
Replacement long-life filter
(Auto grille panel)
Ultra long-life filter unit
(Including filter chamber) (Note 9)
Replacement ultra long-life filter (Note 9,10)
Branch duct chamber (Note 4)
Insulation kit for high humidity (Note 9,11)
Notes:
1. When installing designer panel, body height (ceiling required dimension) is 42 mm higher than standard panel. Designer panel cannot operate
2 and 3 way flow.
2. A dedicated wireless remote controller (BRC16A2) for the auto grille panel is included for lowering and raising the suction grille.
3. When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than standard panel.
4. Circulation airflow is not available with this option.
5. When installing a fresh air intake kit (chamber type), two air outlet corners are closed.
6. It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit.
Introducing higher quantities will increase the operating sound and may also influence temperature sensing.
7. The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. The chamber type is recommended when
more fresh air is necessary.
8. Please order using the name of both components instead of set name.
9. This option cannot be installed to designer panel and auto grille panel.
10. Filter chamber is required.
11. Please use in case temperature / humidity inside ceiling may get over 30°C, 80%RH.
 These panels do not contain the sensing function.
FXFSQ100AVM
Without
KDDP55B160 [Components : KDDP55C160-1, KDDP55B160-2]
T-duct joint
With T-duct
KDDP55B160K [Components : KDDP55C160-1, KDDP55B160K2]
joint
Model
FXFSQ125AVM
BYCQ125EEF
BYCQ125EEK
BYCQ125EAF
BYCQ125EAK
BYCQ125EAPF
BYCQ125EASF
KDBH551C160
KDBH552C160
KDBP55H160FA
KDDP55X160A
KAFP556C160
KAFP557C160
KAFP552B160
KAFP553B160
KDDFP55C160
KAFP551K160
KAFP551H160
KAFP55C160
KAFP55H160H
KDJP55C160
KDTP55K160
32
EDFMT391769A
FXFSQ140AVM
C: 3D112950A