Dhw Plate Heat Exchanger Removal & Replacement - Ideal Heating i305 Installation & Servicing

Pod heat interface unit
Table of Contents

Advertisement

3.13 DHW PLATE HEAT EXCHANGER REMOVAL & REPLACEMENT
1. Isolate and drain the HIU. Refer to Section 3.5.
2. Remove the front panel. Refer to Section 3.4.
3. Remove insulation front section to expose plate heat
exchanger(s). Refer to Section 3.12.
4. Slacken the four pipe nuts on the front face of the LHS
plate. Ensure support is used to not twist the elbow
manifolds. Dispose of fibre washers to prevent re-use.
5. Remove the four screws securing the two plate heat
exchanger retention brackets (upper and lower) to the
chassis.
6. Manoeuvre the plate heat exchanger out of the appliance.
Be aware of any water spillage.
7. Remove the clips from the plate heat exchanger by pulling
the upper one downward and the lower one upward. Lightly
twist and pull the elbows to remove them from the O-ring
seals on the PHE.
8. Fit new blue O-ring seals to the upper most groove on the
4 PHE connection posts (the low groove nearest the PHE
is for the retention clip).
9. Ensure the two indents near the PHE connection posts are
facing inboard.
10. Refit the two 90° elbows to the top of the PHE with their
outlets facing left and right, and the 2 x 60° elbows are
fitted with their outlet facing downwards.
7
5
Installation and Servicing
SECTION 3 - SERVICING
11. Ensure new retention clips are located correctly in the
12. Fit the new plate heat exchanger into the cut out in
13. Refit the four screws securing the upper and lower bracket
14. Replace fibre washers with new (supplied) and spin nuts
15. Torque the 90 degree manifold (TOP) pipe nut connections
16. Torque the 60 degree manifold (BOTTOM) pipe nut
17. Refill the HIU. Refer to Section 2.5.
18. Replace the insulation front section. Refer to Section 3.12.
19. Check that the HIU operates in both DHW & CH modes.
Note: Failure to correctly locate the poisition of the elbows
will prevent the retention clips from being fitted.
slots on the brass elbows and that they are secured to
the correct groove on the PHE connect post. Note: If they
are not correctly fitted the groove nearest the PHE will be
clearly visible. In this case the clip will need to be removed
and the elbows pushed further on the PHE connection
posts and the clip refitted.
insulation back panel – ensure DHW plate size is matched
to plate removed.
Note: Ensure that the depressions on the plate heat
exchanger are facing inboard and match the insulation.
to the chassis, including the upper manifold bracket.
onto manifold threads.
to 40N/m.
connections to 32N/m.