For MC 6504-L PBX in release 11.3
The PBX must be fitted with OCI or OCK cards with the correct index reference for
operating software release 7598 (release 11.3)
♦
LAS card interface, reference HJ2467LD or later (1/4 CLF equipment to be
provided for each LAS card)
♦
power supply ADS850 for remote power of 16 radio base stations under 40 V
♦
power supplies ADS850A and ADS850C (and ADS650) can be used to power 16
radio base stations. You can also use the radio base station local power supply.
See note about locally-powered radio base station below
♦
power supply ADS850IT for remote power of 32 radio base stations under 40 V
♦
maximum number of radio base stations: 64 (2 shelves)
To be able to use the 64 base stations, you must have a mixed expansion shelf and a
second ADS850IT power supply (32 base stations per ADS850IT power supply delivering
1 8 A).
Maximum capacity of radio base stations: 32
Locally-powered radio base stations:
Where the number of radio base stations in a system slightly exceeds the maximum
number specified, the one or two excess radio base stations may be powered locally
using an additional PN840B power pack.