Electronic Window Air Conditioner
WARNING
Read all instructions before use.
To reduce the risk of fire, electric
shock, or injury to persons when
using this appliance, follow the
following precautions:
• Plug into a grounded 3 prong outlet.
• DO NOT remove the ground prong.
• DO NOT use a plug adapter.
• DO NOT use an extension cord.
• Unplug the air conditioner before servicing
• Two people are recommended to lift and install the unit.
• Refrigerant R32 is used. Contact a qualified service
technician for maintenance of the refrigerant.
The electrical ratings for your air conditioner are listed on
the model and serial number label located on the front,
left side of the unit (when facing front).
Recommended Ground Method
For your personal safety, this air conditioner must be
grounded. This air conditioner is equipped with a 3 prong
power supply cord and a grounded plug. To minimize the
possibility of electrical shock, the cord must be plugged
into a 3 prong outlet and grounded in accordance with
all local codes and ordinances. If a 3 prong outlet is not
available, it is the customers responsibility to have a
proper 3 prong outlet installed by a qualified electrician.
Manual del usuario
Servicio de atención al Cliente
US: 1-800-645-2986
It is the customers responsibility:
• To contact a qualified electrician
• To assure that the electrical installation is
adequate and in conformance with the National
Electrical Code, ANSI/NFPA 70 - latest edition, and
all local codes and ordinances.
LCDI Power Cord and Plug
This air conditioner is equipped with an LCD (Leakage
Current Detection and Interruption) power cord that is
required by UL. This power supply cord contains state-
of-the-art electronics that sense current leakage. If the
cord is damaged and leakage occurs, power will be
disconnected from the unit.
The test and reset buttons on the LCDI plug are used to
check if the plug is functioning properly. To test the plug:
1. Plug power cord into a grounded 3 prong outlet.
2. Press RESET (on some units a green light will turn on).
3. Press the TEST button, the circuit should trip and cut
all power to the air conditioner (on some units a green
light will turn off).
4. Press the RESET button for use. You will hear a click
and the A/C is ready for use.
1
Manuel de l'utilisateur
Service à la clientèle
Canada: 888-645-2986
Model 293068 6,000 BTU, Cool Only, 115V
062019

Advertisement

loading
Need help?

Need help?

Do you have a question about the 293068 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Global Industrial 293068

  • Page 1 Service à la clientèle US: 1-800-645-2986 Canada: 888-645-2986 US: 1-800-645-2986 Electronic Window Air Conditioner Model 293068 6,000 BTU, Cool Only, 115V WARNING Read all instructions before use. To reduce the risk of fire, electric It is the customers responsibility: shock, or injury to persons when •...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS ELECTRICAL REQUIREMENTS ................... INSTALLATION HARDWARE ..................INSTALLATION & ASSEMBLY INSTRUCTIONS ............USING YOUR AIR CONDITIONER ................6 ................ CARE AND MAINTENANCE ..................9 TROUBLESHOOTING ....................
  • Page 3: Electrical Requirements

    Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do Not remove the ground prong. Do Not use an adapter. Do Not use an extension cord. Failure to follow these instructions can result in electrical shock, fire, or even death.
  • Page 4: Installation Hardware

    INSTALLATION HARDWARE INCLUDED (Only for E-Star models) NOTE: Save carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter or when not in use.
  • Page 5: Installation & Assembly Instructions

    INSTALLATION & ASSEMBLY INSTRUCTIONS (CONT.) FIG. 1 23" to 36" 584 mm to 914 mm 14 1/2" min EXTERIOR (368mm) STOOL 14½ OFFSET WALL SILL INTERIOR WALL Head Packaging Foam Unit...
  • Page 6 INSTALLATION & ASSEMBLY INSTRUCTIONS (CONT.) Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center the air conditioner and close the window securely behind the top mounting rail. The air conditioner should be slightly tilted to the outside area. NOTE: Check that air conditioner is tilted back approximately ¾”...
  • Page 7 INSTALLATION & ASSEMBLY INSTRUCTIONS (CONT.) FIG. 13 Head For added insulation, cut the supplied insulation foam to the width of the window. Insert the foam between the window sashes to prevent outside air and object from getting into the room. (See FIG. 14) Place the frame lock between the extended accordion panels and the window sill as shown in FIG.
  • Page 8: Using Your Air Conditioner

    Digital Display: Shows the set temperature. Operation modes are: Cool, Dry, Fan, and Auto. Time is displayed using the timer setting. 4. Sleep Press the SLEEP button, all of the display lights will turn off after a while, but the sleep light is always on.
  • Page 9 5. Eco Button: Press the FAN SPEED button 9. Fan Speed Button: to select the fan speed. In COOL MODE you can choose the following settings: HI, MED, LO, or AUTO. In Fan MODE you can choose from HI, MED, and LO. Directional Louvers: Use the horizontal wheels to control horizontal airflow and the air deflectors...
  • Page 10 USING YOUR REMOTE CONTROL...
  • Page 11: Care And Maintenance

    CARE AND MAINTENANCE Clean your air conditioner to keep it looking new, minimize dust build up and for optimal performance. Power off and unplug the air conditioner to prevent shock or fire hazard. The cabinet and front panel of the air conditioner may be dusted The air filter should be checked at least once a with an oil-free cloth or wiped down with a month to see if it needs cleaning.
  • Page 12: Troubleshooting

    Check that there is no damage to the plug fuse / circuit breaker box and replace the fuse or reset the breaker. The temperature setting may not be set correctly. See "The Air Conditioner is Freezing Up" below. Battery Size: AAA - NOTE: Do not mix old and new batteries or different types of AAA batteries.
  • Page 13 For proper water drainage, make The air conditioner is not correctly sure the air conditioner is slightly pitched towards the outside. pitched downwards from the front of the unit to the rear (Refer to installation instructions). NOTE A highly recommended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 minutes. It is also recommended to try another wall outlet.