Download Print this page

Siemens VersiCharge AC Operation And Troubleshooting Manual page 3

Electric vehicle charging station
Hide thumbs Also See for VersiCharge AC:

Advertisement

VersiCharge™ AC Electric vehicle charging station
VersiCharge LED States
Function
Indicates if Metering , A8 (Communication processor), EEPROM, FRAM are detected by M0
1
Power ON self test
(control processor) on power up.
3
Cold Start
EVSE Powers on with EV connected
4
Delay 2 Hr
User activated 2 hr. delay
5
Delay 4 Hr
User activated 4 hr delay
6
Delay 6 Hr
User activated 6 hr delay
7
Delay 8 Hr
User activated 8 hr delay
30
Unit under remote control
Power level, pause or delay is controlled by a remote command ( includes Call to Action (CTA) basic commands)
31
Unit Locked
A remote command locked the unit. Authorization is required to unlock the unit.
32
EV Connected
EVSE is connected to the EV, charging has not started or is being paused/delayed.
36
Pause/Delay
Charging not allowed / authorization required
39
Communication Processor Power Up
Powerup
a
40
Communication Processor - Internal sync up
Processes starting
41
Communication Processor - Waiting to get to AP mode
Internal Wi-Fi set-up in progress, slow blinking green
43
Ready to commission
Pre-Commissioning. Waiting for user's input
44
Network credential accepted
Commissioning Phase - waiting for IP address
42
Failed to Connect to router/gateway
Not commissioned or Not connected to router
46
Connected to Router/Gateway
Commissioning Phase - Aquired IP address
47
Waiting to connect to Versicloud
Commissioning Phase - Unit has Internet access
48
Connected to network and cloud
Commissioning Phase - Finished
a There are two LEDS at the location of the WI-FI indicator. Control Processor (RGB/color) indicates access point (AP) mode and cloud connection using white LED.
Communication Processor indicates intermediate power up and commissioning states.
4
Description
Charging suspended 1-5 min
Charging suspended for 2 hrs
Charging suspended for 4 hrs
Charging suspended for 6 hrs
Charging suspended for 8 hrs
Indicates unit is communication capable
Local overrides using delay button are not allowed
Car Connected LED light lit.
Charging not allowed.
LED Light State
Unit's behavior
Cleared in 5-10 sec of power up
VersiCharge™ AC Electric vehicle charging station
5

Advertisement

loading