Applicability: MAG 144/1 G(E-BE)
OR MAG 144/1 G(H-AT)
OR MAG 144/1 G(H-DE/CH)
OR MAG 144/1 G(LL-DE)
OR MAG 144/1 G(P-BE)
OR MAG 144/1 G(P-CH)
12
11
10
9
8
7
6
1
Down-draught diverter
2
Flue gas sensor
3
Heat exchanger
4
Burner
5
Generator
6
Flow rate se-
lector/temperature
selector
3.3

CE label

The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
0020271929_00 atmoMAG Installation and maintenance instructions
1
2
3
4
5
7
Gas valve assembly
8
Rotary power switch
9
Main switch
10
Electronics box
11
Ignition electrode
12
Monitoring electrode
4

Set-up

4.1

Checking the scope of delivery

1.
Remove the product from its box.
2.
Check that the scope of delivery is complete and intact.
4.1.1
Scope of delivery
Num-
Designation
ber
1
Gas-fired instantaneous water heater
1
Connection accessories that are included
1
Enclosed documentation
4.2

Wall pre-installation

3
60
2
Flush mounting
3
60
2
Surface installation
Install the connections as follows:
1 = Cold water connection R 1/2
2 = Gas connection
3 = R 1/2 hot water connection
Observe the following clearances for all product types:
a = 92 mm
b = 85 mm
c ≈ 100 mm without thermal isolator device
c ≈ 145 mm with thermal isolator device
Set-up 4
1
60
1
60
7