Technical data – Liquid gas G31
Applicability: Belgium
Gas flow rate at max. heat output
Gas connection pressure
Number of burner jets
Burner jet
Burner pressure
Air requirement for combustion at
max. heat input
Air requirement for combustion at
min. heat input
CO₂ content at max. heat output
CO₂ content at min. heat output
Max. flue gas mass flow rate
Min. flue gas mass flow rate
32
MAG 114/1 G(E-
MAG 114/1 G(P-
BE/FR)
BE/FR)
1.69 kg/h
1.69 kg/h
2.5 ... 4.5 kPa
2.5 ... 4.5 kPa
(25.0 ... 45.0 mbar)
(25.0 ... 45.0 mbar)
24
24
0.5 mm
0.5 mm
31.7 mbar
31.7 mbar
38.3 m³/h
38.3 m³/h
28.9 m³/h
28.9 m³/h
7.30 %
7.30 %
3.30 %
3.30 %
4.13 g/s
4.13 g/s
1.10 g/s
1.10 g/s
Installation and maintenance instructions atmoMAG 0020271929_00
MAG 144/1 G(E-BE)
MAG 144/1 G(P-BE)
2.15 kg/h
2.15 kg/h
2.5 ... 4.5 kPa
2.5 ... 4.5 kPa
(25.0 ... 45.0 mbar)
(25.0 ... 45.0 mbar)
28
28
0.51 mm
0.51 mm
34.5 mbar
34.5 mbar
49.84 m³/h
49.84 m³/h
30.04 m³/h
30.04 m³/h
7.15 %
7.15 %
3.20 %
3.20 %
6.82 g/s
6.82 g/s
1.84 g/s
1.84 g/s