Corbin Russwin ASSA ABLOY MP9800 Series Installation Instructions Manual

Multi-point lock se lp10 integrated wired with and without melr option

Advertisement

Quick Links

Installation Instructions
MP9800 Series Multi-Point Lock
SE LP10 Integrated Wired
With and Without MELR Option
FM488 06/20
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
HID and iCLASS are registered trademarks of HID Global Corporation.
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of ASSA
ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Attention Installer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASSA ABLOY MP9800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Corbin Russwin ASSA ABLOY MP9800 Series

  • Page 1 Important: The accuracy of the door preparation is critical for proper functioning and security of this lock. Misalignment can cause premature wear and a lessening of security. For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473) HID and iCLASS are registered trademarks of HID Global Corporation.
  • Page 2: Table Of Contents

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) Table of Contents 1) Regulatory Compliance ............3 2) Warning ................3 3) General Description .............4 4) Specifications / Features ............4 5) Wiring Diagrams ..............6 6) Product Illustrations ............9 7) Installation Instructions ............12 8) Concealed Door Position Switch ........18 9) Operational Check .............19 Copyright ©...
  • Page 3: Regulatory Compliance

    Pour plus d’informations, visitez: www.P65warnings.ca.gov. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
  • Page 4: General Description

    With and Without MELR Option (Electric Latch Retraction) 3) General Description The Corbin Russwin SE LP10 brings flexibility to our Integrated Wired access control solutions for MP9800 series multipoint locks. Featuring multiCLASS SE® Technology from HID Global®, the SE LP10 is ideal for mixed credential environments and enables easy migration to higher security credentials and mobile access.
  • Page 5 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 4) Specifications / Features (Continued) • UL 294 Access Control Ratings: • UL Listed* - UL 294 Indoor Use • CUL Listed - S319: Class 1 Destructive Attack Level 1 •...
  • Page 6: Wiring Diagrams

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 5) Wiring Diagrams Product 8 PIN CONNECTOR 4 PIN CONNECTOR 1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 1-Violet 2-Gray 3-Pink 4-Tan ACCESS CONTROL DEVICES: SE LP10 MP, ElectroLynx wire Color / Function assignments SE LP10 12VDC WIEGAND...
  • Page 7 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 5) Wiring Diagrams (Continued) Typical (UL294*-Compliant) SE LP10 Mortise Application Diagram #1 Tamper will trigger when reader is removed from door and tamper wiring is connected at the panel. Average Peak Average...
  • Page 8 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 5) Wiring Diagrams (Continued) Alternate Indicator Application Diagram #2 (12/24VDC System) Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with panel switch will override reader LED to keep it green. Reader Electronics Requires 12VDC Filtered and Regulated NOTE: If your lock is configured with End of Line Resistors,...
  • Page 9: Product Illustrations

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 6) Product Illustrations SE LP10 MP9800 Series Tools Required • Phillips screw driver (standard size) • Slotted screw driver (standard size) • #8-32 tap & tap drill (for metal door applications) •...
  • Page 10 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 6) Product Illustrations (Continued) SE LP10 MP9800 Series Tools Required • Phillips screw driver (standard size) • Slotted screw driver (standard size) • #8-32 tap & tap drill (for metal door applications) •...
  • Page 11 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 6) Product Illustrations (Continued) ITEM PART # Description Req. WD/MD/AD Inside Trim Assembly Outside Trim Assembly 764F488 MD/AD Inner Chassis Assembly MD/AD Inner Chassis Assembly, Fire (12-) 764F508 MD/AD Monitoring Inner Chassis, Fire (53-/12-53-) 764F498 WD Inner Chassis Assembly (Not shown)
  • Page 12: Installation Instructions

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 7) Installation Instructions 1 Door Preparation Inside A. Verify Hand and Bevel of Door • Check hand of door. The Multi-Point lock may be handed. • Door should be fitted and hung Left Hand Right Hand Reverse...
  • Page 13 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 3 Install Outside Trim and Inside Trim A. Outside Trim 1. For exterior applications, use ET gasket (765F859) to seal ET escutcheon and outside door surface (Fig. 3A). 2.
  • Page 14 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 5 Installation of SE LP10 Reader & Trim Bezel Observe precautions for handling electrostatic sensitive devices. If the SE LP10 reader is installed with a module (Fig. 5A), make sure that the reader is powered down when inserting/removing the module;...
  • Page 15 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 6A Inside Mounting Plate and Wire Connections (Non-MELR) 1. Attach mounting plate using (2) #8 x 1/2” self-drilingl screws (Fig. 6A). 2. Connect 6- and 2-pin connectors from device to 6- and 2-pin connectors on reader harness (Fig.
  • Page 16 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 6B Inside Mounting Plate and Wire Connections (MELR) Install the upper left mounting screw, #8 - 32 x 5/8 Fillister for metal door or #8 x 5/8 self-drilling Fillister for wood doors (Figure 6F).
  • Page 17 SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 7 Fire Plate Installation and Earth Ground Connection 1. Install two (2) #8 x 1/2” self-drill screws in the bottom-most pair of holes in the mounting plate (Fig. 7A). Feed lower left screw through green/yellow ground wire ring terminal.
  • Page 18: Concealed Door Position Switch

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 8B Position Inside Escutcheon & Wires (MELR) 1. Position escutcheon against door by hooking the top edge on the top of the MELR assembly. Verify that no wires are being pinched. 2.
  • Page 19: Operational Check

    SE LP10 Integrated Wired With and Without MELR Option (Electric Latch Retraction) 9) Operational Check For devices without cylinders, go to step 3. 1. For devices with cylinders, insert key into cylinder and rotate. 2. The key will retract the latch and rods, the key should rotate freely. 3.
  • Page 20 HID, the HID logo, iCLASS SE, iCLASS, and Edge are trademarks or registered trademarks of HID Global in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their repsective owners. For installation assistance contact Corbin Russwin 1-800-810-WIRE (9473) • techsupport.corbinrusswin@assaabloy.com FM488 05/20...

Table of Contents