CL33600 Series Cylindrical Lock 2) General Description The Corbin Russwin Access 600 TCRNE1 Series cylindrical lock is designed to interface with existing Wiegand Electrical Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID iCLASS 13.56 technology.
4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-Tan ACCESS CONTROL DEVICES: CL33600 TCRNE1 Series M12 - iCLASS ( ElectroLynx wire Color / Function assignments 12 or 24VDC WIE- WIE- EGND 12 OR 24 VDC GAND GAND Reader Power (LOCK RELAY...
Page 13
CL33600 Series Cylindrical Lock 6) Wiring Diagrams Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock) DIAGRAM #1 – MODE 1: LED WIRE NOT USED = RED LED ‘ON’ WHEN POWERED 12/24VDC SYSTEM Reader Draw = 125mA 12VDC Solenoid Draw = 250mA...
Page 14
CL33600 Series Cylindrical Lock 6) Wiring Diagrams (Continued) Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock) DIAGRAM #2 – MODE 2: LED WIRE TIED TO GROUND = GREEN LED ‘ON’ WHEN POWERED 12/24VDC SYSTEM Reader Draw = 125mA...
Page 15
CL33600 Series Cylindrical Lock 6) Wiring Diagrams (Continued) Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock) DIAGRAM #3 – MODE 3: LED WIRE TIED TO EAC PANEL = EAC PANEL CONFIGURABLE 12/24VDC SYSTEM Reader Draw = 125mA 12VDC Solenoid Draw = 250mA...