While using group function

Symptom
The group function
does not operate.
A new group cannot
be created.
While the recorder is connected to the computer
Symptom
The recorder is not
recognized by the
computer.
Even though the
recorder is
recognized by the
computer, it does
not operate
normally.
The recorder cannot
be used as a storage
device.
Cause/Remedy
• While using a disc without group setting, an attempt was made to select
some group-related menu.
, Use a disc with group setting.
• This is due to the MiniDisc system limitations (in MD mode only).
Group information has been written to the area where the disc name is
stored. The disc name and track names are recorded in the same area,
which can store a maximum of approximately 1,700 characters. If the
total number exceeds this amount, it is impossible to make group
settings.
Cause/Remedy
• The dedicated USB cable is not firmly connected.
, Connect the dedicated USB cable firmly to the recorder and the
computer.
• A USB hub is used.
, Connect the dedicated USB cable directly to the USB port of the
computer.
• Network communication has failed.
, Disconnect the dedicated USB cable, wait at least 2 seconds, and
then reconnect it. If the recorder is still not recognized, disconnect
the dedicated USB cable, restart the computer, and then connect the
dedicated USB cable again.
• When using Windows 2000 Professional, you turned on or restarted the
computer while the dedicated USB cable was connected, and then
disconnected it afterwards.
, Disconnect the dedicated USB cable, restart the computer, and then
reconnect the dedicated USB cable. This problem may be resolved
by updating your Windows operating system so that it contains all
the latest features.
• A USB hub is used.
, Connect the dedicated USB cable directly to the USB port of the
computer.
• You are using the recorder at a place with vibration.
, Use the recorder at a place with no vibration.
• The SonicStage or MD Simple Burner software is active.
, Close the SonicStage or MD Simple Burner software.
• A disc which is not used in Hi-MD mode is inserted.
, Insert a disc used in Hi-MD mode. Only discs used in Hi-MD mode
can be used as a storage media.
73