6. Release the trigger. The LCD displays the torque reading
for 5 seconds.
Adjusting the torque range
The torque range indicates the acceptable range of values
for a successful install. Adjust the torque range to meet the
recommended torque specifi cations.
Adjusting the rundown torque
The rundown torque is the approximate torque value when
the motor stops driving the product. The product tightens the
fastener to the selected preset percentage and then stops.
Manually tighten to reach the target torque.
NOTE: The rundown torque changes the product's output
power. Adjust the rundown torque to prevent over-adjusting
the torquing target of the torque fastener.
Adjusting the target torque
The target torque is the required torque value for the fastener
being installed. Adjust the target torque to meet the required
torque specifi cations.

DISPLAY ALERTS

Memory Almost Full
Dismiss
Memory Full
Dismiss
Battery Over Temperature
Dismiss

TROUBLESHOOTING

Problem
Cause
The product does
The battery is
not turn on when
not installed or
the power button
charged.
is pressed.
Firmware issue
16
English
Memory for Saved Events
The product has a limited
amount of memory dedicated to
saved events.
NOTE: The display prompts
that the memory is close to
being full or reached capacity.
Over Temperature
If the product overheats, a
warning is displayed. Turn off
the product and allow it to cool
down before continuing.
Solution
Insert, replace,
or charge the
battery.
Turn off the
product, and
remove the
battery.
Torque reading
Calibration is
is out of
required.
specifi cation.
The product's
The battery was
settings were
removed before
not saved when
the setting was
the battery was
saved.
removed.
Torque zero error
Torque was
applied while
zeroing.
The product is
over-torqued.
The product was
not calibrated
correctly.
Failure of the
torque sensor
Overtorque
125% of the
maximum torque
rating has been
applied to the
product.
Torque overload
150% of the
maximum torque
rating has been
applied to the
product.
Display prompts
Memory failure
"Memory Error".
Display prompts
The torque is
"Torque
uncalibrated.
Uncalibrated".
Display prompts
The product
"Warning".
needs attention.
Display prompts
The product has
"Battery Over
exceeded the
Temperature".
peak temperature
while running.
Display prompts
The product will
"Certifi cation
soon exceed the
Needed Soon".
expiration date for
certifi cation.
16
Return the
product to a
service centre for
calibration.
Return the
product to a
service centre for
calibration.
Re-enter the
settings, and
press and hold
the power button
to power down
the product
before removing
the battery.
Remove the
torque and re-
zero the product.
Return the
product to a
service centre for
calibration.
Return the
product to a
service centre for
calibration.
Return the
product to a
service centre.
Return the
product to a
service centre for
calibration.
Return the
product to a
service centre for
calibration.
Clear the data in
memory.
Return the
product to a
service centre for
calibration.
Follow the steps
from "Warning" to
"Proceed".
Turn off the
product, and
remove the
battery pack.
Return the
product to a
service centre for
calibration.