FOREWORD
12
Type 3
Disconnection
1.
Hold the connector of the tightening portion and push the body (2)
in straight until sliding prevention ring (1) contacts surface a of the
hexagonal portion at the male end.
2.
Hold in the condition in Step 1, and push until the cover (3)
contacts surface a of the hexagonal portion at the male end.
3.
Hold in the condition in Steps 1 and 2, and pull out the whole body
(2) to disconnect it.
Connection
1.
Hold the connector of the tightening portion and push the body (2)
in straight until the slide prevention ring (1) contacts surface a of
the hexagonal portion at the male end to connect it.
PC490LC-10
PUSH PULL COUPLER
00
00
00
00-29 b