Maintenance

Before serving the machine always
disconnect the machine from the power
supply by removing the power cable
from the socket !
Repair must only be carried out by a
GERIMA trained technician!
Improperly repaired machines are
hazzard!
Increased risk of injury
Machine does not function correctly!
Hot carbide inserts and milling head!
Burn hazzard!
Wear protective gloves when replacing
the carbide inserts!
Maintenance plan:
Part to be serviced
Service 1:
Ventilation slots
Service 2:
Carbide inserts
Service 1:
To ensure that the machine can be cooled properly, the
ventilation slots must be kept clean. To avoid damaging
the motor winding it is important that no foreign matter
(e.g. chips) enter the motor compartment. Clean the
motor compartment regularly by blowing compressed air
through it.
©
Type of mainte-
Service
nance work
Daily
Machine
operator
Rotate or replace as
Machine
necessary
operator
Blunt tool can cause damage!
Blunt tool can overload the machine!
Inspect milling tools regulary for signs of
wear.
Wear protective gloves when changing
or readjusting the carbide inserts!
Maintenance
procedure
Clean ventilation
Brush, cloth,
slots
compressed air
See page
Torx-wrench
15
Maintenance
Materials
Order-nr.
required
./.
See page
T15
15
18