HYDRAULIC PUMP
6.5.5
Minimum Angle Servo Cover Replacement
CAUTION
Before removing the cover, through-
ly clean the external surfaces of the
servo cover and the surrounding
area on the motor to prevent con-
tamination.
(1)
Remove the four screws retaining the servo
cover to the end cap using an 8 mm internal
hex wrench (Fig. 25).
Figure 25. Servo Cover Removal
(2)
Remove the o---rings between the cover and
end cap and discard.
(3)
Coat new o---rings with petroleum jelly and
install on the end cap. Install the cover onto
the end cap torquing to 58 ft. lbs. (78 Nm).
Refer to Figure 26.
Figure 26. Servo Cover Installation
GROUP 3025
3025- - 9A, Page 17
Need help?
Do you have a question about the 51 Series and is the answer not in the manual?