Viessmann VITOLIGNO 250-S Operating Instructions Manual page 49

Wood gasification boiler for logs up to 50 cm or 100 cm long
Table of Contents

Advertisement

Approved logs
(cont.)
Property class
Diameter
Length for Vitoligno 250-S with 40, 50, 60
and 75 kW
Length for Vitoligno 250-S with 85, 100,
120 and 170 kW
Water content
Approved wood in small pieces
A proportion of the wood fuel may be wood in small pieces as described below.
Coarse woodchips:
Class B1/P31S/M20/A0.8 (properties to
EN ISO 17225-4)
Approved fuel for pressure-jet oil burners
Approved fuel: Extra light fuel oil
Non-approved fuels
Danger
The use of unsuitable fuels leads to risk of poi-
soning. Burning waste or wood that has been
treated with timber preservatives or has been
coated with materials containing organic halo-
genated compounds creates highly poisonous
flue gases.
Only use permissible fuels.
!
Please note
If unsuitable fuels are used, there is a risk of
damaging the heating system. Burning waste or
wood that has been treated with timber preser-
vatives or has been coated with materials con-
taining organic halogenated compounds may
result in serious corrosion damage in the boiler.
Only use permissible fuels.
The following must never be burnt:
anthracite and coke
Wood waste coated in materials made of organic
halogenated compounds (PVC)
Wood pellets
To EN ISO 17225-5
B
D15
L50
L100
M20
Joinery waste:
Glued wood and wood remnants
They must not be coated in or contain wood preser-
vative.
The edge length must be > 5 cm.
Ordering fuel
Additional details
Hardwood: 5 to 15 cm
Softwood: 5 to 12 cm
Max. 50 cm
Max. 100 cm
Max. 20 %
49