Cleaning the ash chamber
3. Pull out the ash pan. Empty the ash into a suitable
container.
!
4.
Please note
Risk of fire due to hot ashes! In unsuitable
vacuum cleaners, hot ashes can ignite filters
and plastic materials.
1. Use an ash vacuum cleaner that is spe-
cially designed for this purpose.
2. Never use domestic vacuum cleaners
made of plastic with fabric/paper filters.
Clean the entire ash chamber with a hand brush or
an ash vacuum cleaner (optional).
Cleaning the tubular heat exchanger
A
Fig. 35
Cleaning cover, heat exchanger
A
Turbulators with mounting brackets
B
Locking device, cleaning cover
C
1. Release lock
C
of the cleaning cover. Initially open
cleaning cover
A
up to the lock.
2. Turn the mushroom handle to unlock the cleaning
cover and fully open it.
Boiler size
Vitoligno 250-S with 40, 50, 60, 75, 100 and 170 kW
Vitoligno 250-S with 85 and 120 kW
Repeat steps 4 to 6 below until the tubular heat
exchanger is clean:
(cont.)
5. Refit the ash pan. Close the ash chamber door.
B
C
3. Check the gaskets for wear and damage. Replace
Turbulators installed as standard
Yes
No
these if required.
Maintenance