Item
Image quality
・ The resolution must be in compliance with the following
Resolution at AF
・ There must not be an outstanding dust in a picture.
Dust appearance
・When the picture center (within the circle whose diameter is
Criteria
values in all the postures of the EIAJ chart evaluation.
Hight 5M(2595)
・Center horizontal/vertical: 1200 TV pcs.
・Periphery horizontal/vertical: 950 TV pcs.
Normal 5M(2595)
・Center horizontal/vertical: 1200 TV pcs.
・Periphery horizontal/vertical: 950 TV pcs.
Normal (2048)
・Center horizontal/vertical: 900 TV pcs.
・Periphery horizontal/vertical: 650 TV pcs.
PC screen (1024)
・Center horizontal/vertical: 450 TV pcs.
・Periphery horizontal/vertical: 300 TV pcs.
TV screen (640)
・Center horizontal/vertical: 250 TV pcs.
・Periphery horizontal/vertical: 150 TV pcs.
80% of the short side) is Zone I and its outside is Zone II, the
light reduction against the periphery must be as follows :
a
Zone Ⅰ
4 or less
Zone Ⅱ
  10 or less 
  
a: 1.5% or less
b : More than 1.5% and less than 3.0%
(Take a picture of the 5100K viewer under the condition of
the "T" end, aperture "open" and "without ND" and also,
"with ND". Check the image.)
(Check it by PC.)
-R・L10 -
EIAJ chart
Photoshop
Siemens chart
・AUTO
・Image quality priority
mode
・ Equip the 5100K viewer
with a chart in all the
p o s i t i o n s a n d a t t h e
distance of 0.4m or more
and shoot an object in
the full range of angle of
view.
・Open the recorded
image data file through
Photoshop and check the
resolution visually.
Photoshop
CRT monitor
b
0
2or less
INC
VAA76013-R.3709.A