Item
Lens barrel
Zoom
Focus
Shooting with a speed light
Light adjustment
accuracy
Guide No. FULL
(ISO100・m)
Recycling time
Wrong flash
Criteria
・Neither deviation nor image slant nor "caught-in-mechanism"
motion.
・No abnormal operation.
・No abnormal operation.
・Tele 0.4 ~ 2.5m
・Wide 0.5 ~ 3.0m
・Micro-wide 0.4 ~ 3.0m
・FULL 7.0 ±0.4EV
(Charge SB with a full-charged battery for 20 seconds. Flash
and measure within 1 second. Distance: 1 m)
・Within 8 seconds
・No wrong flash.
(Check by inserting/removing a battery, giving a light shock
and operating mode buttons.)
-R・L10 -
INC
VAA76013-R.3709.A
Tools
Visual check
Standard reflection plate
Flash meter
Secondary battery
New primary-battery
Stopwatch
Fresh secondary battery