AG Electronica XBee 2 Series Manual page 51

Table of Contents

Advertisement

www.agelectronica.com
XBee Series 2 ZigBee OEM RF Modules v1.x2x  [2007.07.019]
Frame ID (byte 5)
Identifies the UART data frame for the host to
correlate with a subsequent ACK
(acknowledgement).
Setting Frame ID to '0' will disable response
frame.
www.agelectronica.com
Figure 7‐13. ZigBee Transmit Request.
Start delimiter
Length
0x7E
MSB
LSB
API-specific Structure
API Identifier
Identifier specific data
0x10
16-bit Destination Network Address
(bytes 14-15)
MSB first, LSB last.
Set to 0xFFFE for
Broadcast TX or if Network
Address is not known
64-bit Address (bytes 6-13)
MSB first, LSB last.
Broadcast =
0x000000000000FFFF
© 2007 Digi International, Inc.
Frame Data
Checksum
1 Byte
cmdData
Options (byte 17)
0x08 - Send multicast transmission. (Unicast
sent if not set.)
All other bits must be set to 0.
Broadcast Radius (byte 16)
Sets maximum number of hops a broadcast
transmission can traverse. If set to 0, the TX
radius will
be set to the network maximum hops value
(10).
www.agelectronica.com
Chapter 7 ‐ API Operation
RF Data: Bytes (s) 18-n
Up to 72 Bytes
per packet