Redline SMOKE PRO AIR COMPLETE 95-0051 Operation Manual

Diagnostic leak detector

Advertisement

Quick Links

SMOKE PRO
DIAGNOSTIC LEAK DETECTOR
OPERATION MANUAL
REDLINE MODEL NO: 95-0051
Manufactured in California, USA
AIR COMPLETE
®
*

Advertisement

Table of Contents
loading

Summary of Contents for Redline SMOKE PRO AIR COMPLETE 95-0051

  • Page 1 SMOKE PRO AIR COMPLETE ® ™ DIAGNOSTIC LEAK DETECTOR OPERATION MANUAL REDLINE MODEL NO: 95-0051 Manufactured in California, USA...
  • Page 2: Table Of Contents

    Under DashBoard Leaks your shop and see how it will help you to work smarter and Troubleshooting......make more money. Maintenance......... Portability. Performance. Profit. Air Complete is the complete ™ Warranty ........diagnostic solution. Zachary Parker President Redline Detection, LLC...
  • Page 3: Specifications

    SPECIFICATIONS L x W x H 8 in. x 10 in.x 12.5 in. (20 cm x 25 cm x 33 cm) Weight 10.3 lbs. (4.5 kg) Shipping Weight 18 lbs. (8 kg) Power Supply 12 Volts DC Power Consumption 8 amps Output Pressure 0.5 PSI / 13.0 in.
  • Page 4: Reference Guide

    REFERENCE GUIDE FRONT VIEW 1. Compound Pressure Gauge Indicates amount of pressure or vacuum Allows for Decay / Leak Down test to confirm repair is 100% complete 2. Flow Meter Measures leak size as small as 0.010” 3. Flow Control Knob Releases vapor / pressure into system by opening the flow control valve Close flow control valve to lock out...
  • Page 5: Safety

    SAFETY The procedures in this operation manual are intended to be basic guidelines for users to practice using this diagnostic leak detector This operation manual is not intended to be used in place of common sense: • Use this equipment in the manner specified by the manufacturer •...
  • Page 6: Accessories

    ACCESSORIES INCLUDED Handle / Hook [PN 96-0053] To properly carry Air Complete and hang under hood or chassis Hex Key [PN 80-0009] To remove / replace fluid fill plug OEM-Approved Vapor Producing Fluid [PN 96-0039] Vapor Producing Fluid will perform over 1,000 typical tests (500+ per bottle) IMPORTANT: Contains NO Dye / Contaminants EVAP Service Tool Kit [PN 96-0003]...
  • Page 7 ACCESSORIES INCLUDED EasyEVAP™ [PN 95-0030] This universal Fuel Filler Neck Connector system fits 100% of vehicles to simplify EVAP testing Sealing Disks [PN 96-0017-12] Creates an air-tight seal with any filler neck CapAdapt™ Capless Adapter [PN 96-0054] Opens throat of cap-less filler necks Accessory Storage Case [PN 91-0011] ADDITIONAL ACCESSORIES Extended Accessory Kit [PN 95-0005]...
  • Page 8: Set Up

    SET UP 1. FILL / ADD VAPOR PRODUCING FLUID Remove Fluid Fill Plug with hex key Pour OEM-Approved Vapor Agent into Fluid Fill Port until fluid level is near top of Fluid Fill Port Replace Fluid Fill Plug Do not overfill Only takes 2 fl.
  • Page 9: Testing For Leaks

    TESTING FOR LEAKS 4. TESTING WITH SMOKE Push smoke test button to begin a 5-minute vapor cycle VAPOR INDICATOR: Red Light: Vapor is Generating Flashing Red Light: See Troubleshooting (Pg 11) No Light: No Vapor Generating Turn Flow Control Knob counter-clockwise to release smoke / pressure Flow Meter indicates flow and measures leak size Use provided Halogen Inspection Light to locate leaks Perform repair(s) as needed...
  • Page 10: Intake System / Vacuum Leaks

    HOW TO DIAGNOSE INTAKE SYSTEM & VACUUM LEAKS This procedure will locate leaks in vacuum lines as well as manifolds, EGR valves, oil seals, gaskets, solenoids, o-rings, ducting, throttle shafts, diaphragms, canisters, and more For best results, test in a draft-free area 1.
  • Page 11: Evap - Fuel Vapor Recovery System Leaks

    HOW TO DIAGNOSE EVAP LEAKS Leaks in the EVAP system, or fuel vapor recovery system, are frequently the cause for check engine lights. Using a diagnostic leak detector, these leaks can now be quickly diagnosed and repaired, making them profitable services for repair facilities 1.
  • Page 12: How To Diagnose Leaks

    HOW TO DIAGNOSE EXHAUST LEAKS This test is most effective when exhaust system is cold Thermal expansion may cause small leaks to seal 1. Insert appropriate Cone Adapter into the end of the tailpipe If the vehicle has dual exhaust with cross over system, plug the other tailpipe to seal the system 2.
  • Page 13: Troubleshooting

    Connect to a fully-charged 12-Volt battery Never use battery charger as power source Amber or Red Light Flashing Open Circuit / internal component Contact Redline Technical Support No Air Flow Open the flow control valve Check hoses are not kinked or pushed into...
  • Page 14: Maintenance

    MAINTENANCE CHECK FLUID LEVEL Remove Fill Plug from Fluid Fill Port with hex key Pour OEM-Approved Vapor Agent into Fluid Fill Port until fluid level is near top of the Fluid Fill Port Replace Fluid Fill Plug Check fluid level every 75 - 100 tests CLEAN FLOW METER Disconnect air aupply and power from the machine Remove the flow meter’s top plug with a wrench...
  • Page 15: Warranty

    Any Redline- manufactured vapor chamber that leaks, cracks, or separates in any way shall be repaired or replaced by Redline at no charge. Products are only to be used by persons having skill and knowledge in the automotive repair field, and improper use or maintenance may cause serious injury.
  • Page 16 +1 714-451-1411 www.RedlineDetection.com Manufactured By Redline Detection, LLC MADE IN USA with global components 01-0091/A...

Table of Contents