Summary of Contents for Redline GM POWER SMOKE RLD950103GM

  • Page 1 ™ DIAGNOSTIC LEAK DETECTOR OPERATION MANUAL P/N RLD950103GM...
  • Page 2: Table Of Contents

    CONTENTS Specifications ..............................1 Reference Guide ............................. 2 Safety ................................. 3 Accessories ..............................4 GM Power Smoke™ Set up ........................... 5 Adaptor Installation ............................6 Testing for Leaks ............................7 - 8 Trouble Shooting ............................. 8 Warranty ................................9 Replacement Parts ............................9 Technical Support: 1-866-55-SMOKE +1 714-451-1411 GM Technical Support: 1-800-GM-TOOLS...
  • Page 3: Specifications

    SPECIFICATIONS Dimensions 9 in. x 9 in. x 15 in. (23 cm x 23 cm x 38 cm) Weight - GM Power Smoke™ 19 lbs. (9 kg) Weight - Accessory Kit Only 16 lbs. (8 kg) Weight - Shipping 41 lbs. (18.5 kg) Power Supply 110-240V AC or 12V DC Pressure Supply...
  • Page 4: Reference Guide

    REFERENCE GUIDE FRONT VIEW 1. F ontrol ariable eleases vapoR pRessuRe into the system lose flow ContRol valve to loCk out system foR pRessuRe deCay testing 2. S yStem reSSure auGe isplays the baCk pRessuRe of system undeR test 3. F eter easuRes flow Rate into system undeR test 4.
  • Page 5: Safety

    GM Power Smoke™ utilizes higher test pressure that may damage components in evaporative emission systems. Redline Detection manufactures OEM approved EVAP leak detectors such as, Smoke Pro® Total-Tech® [ 95-0003/C ] and Smoke Pro Air Complete™ [ 95-0051 ] which are specifically designed for EVAP system and general repair diagnostics.
  • Page 6: Accessories

    ACCESSORIES QUANTITY 1. Accessory Storage Case [ 910006 ] Store all included accessories. 2. GM Graduated Adaptor (4 tier) [ 960202] Quad diameter adaptor to test induction system. 3. GM Graduated Adaptor (5 tier) [ 960203] Triple diameter adaptor to test induction system. 950081/ PowerSmoke™...
  • Page 7: Gm Power Smoke™ Set Up

    SET UP 1. FILL / ADD APPROVED VAPOR PRODUCING FLUID a. Remove vapor producing fluid fill plug with hex key b. Pour GM-Approved Vapor Producing Fluid into vapor producing fluid fill port 960036 Note: Use only GM-Approved Vapor Producing Fluid part number : RLD c.
  • Page 8: Adaptor Installation

    • Debris, protrusions and residue in the Intake / Exhaust system could weaken and / or rupture the bladder of the PowerSmoke™ Adaptor. Bladder failures due to misuse or abuse are not covered by warranty. Redline Detection shall not be responsible for any incidental or consequential damages •...
  • Page 9: Testing For Leaks

    TESTING FOR LEAKS Intake System Leak Testing This test will find any leaks in ducting, charged air cooler, turbocharger, intake manifold, throttle body, seals, gaskets, hoses, etc. Seal off intake system by installing GM Graduated Adaptor or PowerSmoke™ Adaptor (see instructions) into intake ducting after air cleaner box.
  • Page 10: Troubleshooting

    • Check polarity if 12V DC is selected • Check fuse if AC Power is selected Red Light Flashing • Open circuit / internal component • Contact Redline Technical Support 866-55-SMOKE or +1 714-451-1411 Email: info@RedlineDetection.com No Air Flow • Check connection to compressed air •...
  • Page 11: Warranty

    Redline’s liability under this warranty is limited to: (1) repair or replacement of any parts or product which are determined to be defective; or at Redline’s sole option (2) refund of the purchase price.
  • Page 12 Manufactured By Redline Detection, LLC * with global components Technical Support +1 714-451-1411 Shop Online: www.RedlineDetection.com...

Table of Contents