BENCH TEST
Refer to Connection (Wiring) Diagram.
Note: [ ] indicates keypad key i.e. [2], [
Shaded addresses are not applicable. Any values must be
entered i.e. [2
].
ND
1. To set zones in non-alarm state (keypad zone lights off),
install green (1K
) resistors across zone terminals.
OHM
2. Connect keypad. Install green (1K
zone.
3. Connect sounder or install green (1K
terminal.
4. Connect AC, connect battery.
5. [
] key illuminates, due to timer loss. Push [
TRBL
trouble conditions, (see Keypad Trouble Display).
6. All keypad lights should be off and keypad should respond to
Master code arming and disarming.
7. Master Code: default 474747.
8. Keypad Programming (default installer code 747474) .
(Used to program "Access to Upload/Download" and "Installer Code")
All digits from 0 to F are valid. (See Interpreting Hexa Values)
Programming values are programmed into memory locations from
address 000 to 007.
1) Press [
] + installer code (default 747474)
ENTER
2) Key [
] will flash (programming mode)
ENTER
3) Enter 3 digit memory address
4) Enter 2 digit data (See Hexa Display to read value )
5) To erase, press [
CLEAR
6) Go to step 3 for next address
To exit programming mode press [
ACCESS TO UPLOAD/DOWNLOAD:
/__ Number of rings before answer (default 8 rings)
000:
Enter "[2
][2
]" panel will not answer.
ND
ND
PANEL IDENTIFIER (default code "empty")
001: __/__
002: __/__
PC PASSWORD (default code "empty")
003: __/__
004: __/__
INSTALLER CODE: (default code 747474)
Full access to programming,(all addresses except 008-058)
No access to arming/disarming and access code programming
(can be used to modify installer code)
Important: Use only numeric keys from [1] to [10] (key [10] = 0) to
enter installer code.
005: __/__
006: __/__
]. [
], [
ENTER
CLEAR
MEM
) resistor across keypad
OHM
) resistor across "BELL"
OHM
] to view
TRBL
]. To save press [
]
ENTER
]
CLEAR
007: __/__
].
KEYPAD TROUBLE DISPLAY
Key "ON" =
[1] No battery/low voltage [7] Communicator report failure
[3] AC failure
[4] Bell disconnect
[5] Maximum bell current
[6] Max auxiliary current
*
To clear timer loss trouble, see Key Access Programming [
Press [
] to clear troubles.
CLEAR
INTERPRETING HEXA VALUES
KEY
[1] - [9]
[10]
[11]
[12]
[
]
BYP
[
]
MEM
[
]
TRBL
[2
]
ND
HEXA DISPLAY
If key is lit = 8
If key is lit = 8 = 4
No display = SKIP (empty)
10 = [0] = [A]
- 1 -
SOFTWARE VERSION 1.0
*
[8] Timer loss
[9] Tamper or zone wiring failure
[10] Telephone line failure
[11] Fire loop trouble
HEXA VALUE
DECIMAL VALUE
1 - 9
1 - 9
A
0
B
11
C
12
D
13
E
14
F
15
skip, null, not programmed
Value of
= 4
=
2
=
1
2
ND
digit = 10
( 8 + 2 = 10)
Value of
1
ST
digit = 3
( 2 + 1 = 3)
=
2
=
1
VALUE
No light = 0
PG728-960603
].
MEM
= "30"
Need help?
Do you have a question about the ESPRIT728 and is the answer not in the manual?
Questions and answers