B-38
If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
p.c. computer application or Palm O.S. application is
required to change the passcode
Memory Value
200
High Limit
HI = 200
WELD WFS
WELD MODE
ARC CONTROL
Parameter Name
If the passcode has been set to zero (0000), SETUP will
illuminate on the MSP4 panel and the display will show
the following:
Four items show on the MSP4 panel.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the MSP4 encoder is rotated. Press the
right button on the MSP4 panel to select the item to
change.
200
HI = 200
WELD WFS
WELD MODE
ARC CONTROL
Rotate to
Change
Value.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory
chosen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that can-
not be changed, set the high and low limits to the
same value.
All manuals and user guides at all-guides.com
OPERATION
Low Limit
LO = 180
START OPTIONS
END OPTIONS
LO = 180
START OPTIONS
END OPTIONS
Press to
select item
to change.
POWER FEED™ 25M
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The MSP4 will ask to save or discard
the limit changes just made. Press the left MSP4 for
button (YES) to save and enable the limits and exit.
Press the right MSP4 button (NO) to exit and leave
limits unchanged.
Enabling/Disabling Limits
Enable/Disable
Limits: Press
10 seconds
A
GUN B
1
2
5
6
Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when the
MSP4 display shows the following:
MEMORY 2
ENABLE/DISABLE
WELD MODE
ARC CONTROL
If the passcode does not equal zero, enter the passcode
now. If the passcode is zero (0000), SETUP will light
ENABLE
Yes
WELD MODE
ARC CONTROL
and the MSP4 displays the following:
Press the left MSP4 button (YES) to enable limits or
the right MSP4 button (NO) to disable limits. Disabling
limits does not change any limits values that may
have been previously set.
B-38
4
3
7
8
LIMITS
START OPTIONS
END OPTIONS
LIMITS?
No
START OPTIONS
END OPTIONS