Advertisement

Quick Links

TTK 70 HEPA
EN
OPERATING MANUAL
DEHUMIDIFIER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec TTK 70 HEPA

  • Page 1 TTK 70 HEPA OPERATING MANUAL DEHUMIDIFIER...
  • Page 2: Table Of Contents

    • Check accessories and connection parts for possible Follow the manual damage prior to every use of the device. Do not use any Information marked with this symbol indicates that the defective devices or device parts. operating manual must be observed. dehumidifier TTK 70 HEPA...
  • Page 3 • Only install the device in compliance with the national installation regulations. • Observe the national gas regulations. • Only install, operate and store the device TTK 70 HEPA in a room measuring more than 4 m dehumidifier TTK 70 HEPA...
  • Page 4 P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well- ventilated place. Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company! dehumidifier TTK 70 HEPA...
  • Page 5: Information About The Device

    In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living and working spaces. Because of the heat radiation generated during operation, the room temperature may rise slightly. dehumidifier TTK 70 HEPA...
  • Page 6: Transport And Storage

    • Leave the device to rest for 12 to 24 hours, so the refrigerant can accumulate within the compressor. Wait 12 to 24 hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided. dehumidifier TTK 70 HEPA...
  • Page 7: Assembly And Start-Up

    • Make sure that no curtains or other objects interfere with the air flow. • When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations. dehumidifier TTK 70 HEPA...
  • Page 8: Operation

    Illuminated when a high fan speed is LED II • The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the device is switched off. dehumidifier TTK 70 HEPA...
  • Page 9 ð The indication of the currently selected operating mode flashes. 2. Repeatedly press the MODE button (12) until the operating mode LED Dehumidification (30) flashes. ð The LED of the selected operating mode flashes for approx. 5 seconds before the operating mode is activated. dehumidifier TTK 70 HEPA...
  • Page 10 The previous settings are saved except for the timer. Auto stop function Once the condensation tank is full, the device will stop automatically. The  LED (20) is illuminated. Empty the condensation tank as described in section Emptying the condensation tank. dehumidifier TTK 70 HEPA...
  • Page 11: Available Accessories

    Only use accessories and additional equipment specified in the operating manual. Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury. Designation Article number HEPA filter 7.710.000.024 dehumidifier TTK 70 HEPA...
  • Page 12: Errors And Faults

    If malfunctions occur nonetheless, chapter Maintenance). If the condenser is dirty, have it check the device according to the following list. cleaned by a specialist company or by Trotec. The device does not start: The device is loud or vibrates: •...
  • Page 13: Maintenance

    10. Date: ........11. Date: ........12. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........13. Date: ........14. Date: ........15. Date: ........16. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........dehumidifier TTK 70 HEPA...
  • Page 14 Clean the housing with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. dehumidifier TTK 70 HEPA...
  • Page 15 1. Remove the cover of the air inlet. accordance with the national regulations and remove the new HEPA filter from the plastic cover. 4. Insert the cleaned / new HEPA filter into the device. Make sure that the strip is positioned as indicated. dehumidifier TTK 70 HEPA...
  • Page 16 4. Allow the filter to dry completely. Do not insert a wet filter reduced (see chapter Errors and faults). into the device! 1. Remove the cover of the air inlet. 5. Reinsert the air filter into the cover. dehumidifier TTK 70 HEPA...
  • Page 17 If the condensation tank is full or not installed correctly, the  In doing so, make sure that the condensation tank is  LED (20) will be illuminated. inserted correctly, for otherwise the device cannot be 1. Take the condensation tank out of the device. switched back on. dehumidifier TTK 70 HEPA...
  • Page 18: Technical Annex

    Dimensions (length x width x height) 225 x 340 x 565 mm Minimum distance to walls and other objects A: top 50 cm B: rear 50 cm C: side 50 cm D: front 50 cm Weight 14.5 kg dehumidifier TTK 70 HEPA...
  • Page 19 Circuit diagram dehumidifier TTK 70 HEPA...
  • Page 20 Water Level Mark Capacitor Control PCB Exhaust Pipe Motor Top Cover Block Main Body Membrane Compressor Assembly Return Pipe Inlet Frame Universal Wheel Sensor HEPA-Filter Base Fixed Mount (L) Air filter Condenser & Evaporator Back Cover dehumidifier TTK 70 HEPA...
  • Page 21: Disposal

    You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 22 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

1120000069

Table of Contents