  • Page 1 TTK 75 ECO ORIGINAL INSTRUCTIONS DEHUMIDIFIER...
  • Page 2: Table Of Contents

    Notes regarding the instructions ......... 2 Safety .................. 2 Information about the device.......... 5 TTK 75 ECO Transport and storage............ 6 Assembly and start-up............ 7 https://hub.trotec.com/?id=43852 Operation ................ 8 Safety Available accessories............ 9 Read this manual carefully before starting or using the Errors and faults.............. 10 device. Always store the manual in the immediate vicinity Maintenance ................ 11...
  • Page 3 • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air- conditioning or by Trotec. dehumidifier TTK 75 ECO...
  • Page 4 Safety chapter. manufacturer upon request. Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. dehumidifier TTK 75 ECO...
  • Page 5: Information About The Device

    Residual risks Behaviour in the event of an emergency 1. Switch the device off. Danger 2. Disconnect the device from the mains feed-in: Hold onto Natural refrigerant propane (R290)! the mains plug while pulling the power cable out of the H220 –...
  • Page 6: Transport And Storage

    Device depiction Transport and storage Note If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Please note that additional transport regulations might apply to devices containing flammable refrigerants. The equipment's arrangement and the maximum number of components to be transported together can be gathered from the applicable transport regulations.
  • Page 7: Assembly And Start-Up

    • Do not create tripping hazards when laying the power Assembly and start-up cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges. Scope of delivery • Make sure that extension cables are completely unrolled. •...
  • Page 8: Operation

    Auto stop function Operation If the condensation tank is full or not inserted correctly, the Notes: device will stop automatically. • Avoid open doors and windows. Operating hours counter • After being switched on, the device operates fully The device is equipped with an operating hours counter (10). automatically.
  • Page 9: Available Accessories

    3. Guide the hose through the hole in the device's side panel. The device comes with a hot gas automatic defrost system based on the bypass procedure. Here, the hot gas of the refrigerant circuit is used actively for fast and effective defrosting.
  • Page 10: Errors And Faults

    • Check the room temperature. Observe the device's device to a specialist company for cooling and air-conditioning permissible operating range according to the technical or to Trotec for repair. data. • Ensure that the relative room humidity complies with the technical data.
  • Page 11: Maintenance

    Maintenance intervals Maintenance Maintenance and care interval before every as needed at least every at least every at least every at least start-up 2 weeks 4 weeks 6 months annually Check the air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the...
  • Page 12 Activities required before starting maintenance device cleaned by a specialist company for cooling and Warning of electrical voltage air-conditioning or by Trotec. Do not touch the mains plug with wet or damp hands. 5. Put the air filter back in.
  • Page 13 2. Clean the filter using a slightly damp, soft, lint-free cloth. Emptying the condensation tank If the filter is heavily contaminated, clean it with warm If the condensation tank is full or not installed correctly, the water mixed with a neutral cleaning agent. condensation tank indicator light (9) will be illuminated.
  • Page 14: Technical Annex

    4. Refit the condensation tank into the device. Technical annex Make sure not to damage the float when inserting or removing the condensation tank. Technical data In doing so, make sure that the float is positioned correctly. Parameter Value Also make sure that the condensation tank is inserted Model TTK 75 ECO correctly, otherwise the device cannot be switched back...
  • Page 15 Wiring diagram dehumidifier TTK 75 ECO...
  • Page 16 Overview of spare parts Spare parts list Spare Part Spare Part Spare Part Water Tank Handle Capacitor (Compressor) Coil Assembly Housing Suction Tube Capillary Tube Power Cord Discharge Tube Three Exit Tube II Discharge Tube II Three Exit Tube Three Exit Tube Defrost Tube Bypass Valve Gas-In Tube...
  • Page 17: Disposal

    You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.
  • Page 18 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...