    Information marked with this symbol indicates that the • Check accessories and connection parts for possible operating manual must be observed. damage prior to every use of the device. Do not use any defective devices or device parts. dehumidifier TTK 71 E...
  • Page 3 (e.g. open flames, an active gas appliance or an electric heater). • Please note that the refrigerant is odourless. • Only install the device in compliance with the national installation regulations. • Observe the national gas regulations. dehumidifier TTK 71 E...
  • Page 4 Safety chapter. manufacturer upon request. Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. dehumidifier TTK 71 E...
  • Page 5: Information About The Device

    2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. dehumidifier TTK 71 E...
  • Page 6: Transport And Storage

    • Place no further devices or objects on top of the device to Air inlet with air filter prevent it from being damaged. Condensation drain hose connection Condensation tank with filling level indicator Air filter Feet Transport handle Air outlet dehumidifier TTK 71 E...
  • Page 7: Assembly And Installation

    • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater). • Only put up the device in an upright, stable position on firm ground. dehumidifier TTK 71 E...
  • Page 8 • Ensure that the float inside the condensation tank is inserted correctly. • Ensure that the condensation tank is empty and inserted correctly. Connecting the power cable • Insert the mains plug into a properly secured mains socket. dehumidifier TTK 71 E...
  • Page 9: Operation

    Is displayed when the ð The desired relative room humidity level is indicated on the condensation tank is full or not segment display (10). installed correctly. 15 DEFROST indication Is displayed when automatic defrosting is in progress. dehumidifier TTK 71 E...
  • Page 10 The DEFROST indication (15) is illuminated during automatic 1. Press the TIMER button (17). defrosting. ð The TIMER indication (16) is enabled. 2. Press the increase value (11) or decrease value arrow button (9) to set the desired number of hours. dehumidifier TTK 71 E...
  • Page 11: Errors And Faults

    • From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec. • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
  • Page 12 Only then switch the device back on. Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair. dehumidifier TTK 71 E...
  • Page 13: Maintenance

    10. Date: ........11. Date: ........12. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... 13. Date: ......... 14. Date: ........15. Date: ........16. Date: ........Signature: ........ Signature: ......... Signature: ......... Signature: ......... dehumidifier TTK 71 E...
  • Page 14 Trotec. Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals. Replace illegible safety signs! dehumidifier TTK 71 E...
  • Page 15 (see chapter Errors and faults). 1. Remove the air filter from the device. 3. Allow the filter to dry completely. Do not insert a wet filter into the device! 4. Reinsert the air filter into the device. dehumidifier TTK 71 E...
  • Page 16 If you do not intend to use the device for a considerable time: 3. Rinse the tank with clear water. Clean the tank regularly • Store the device according to the Storage chapter. using a mild cleaning agent (no detergent!). dehumidifier TTK 71 E...
  • Page 17: Technical Annex

    0.000165 t Water tank 2.3 l Sound pressure level 48 dB(A) Dimensions (length x width x 220 x 350 x 550 mm height) Minimum distance to walls and other objects A: top: 30 cm B: rear: 20 cm C: side: 20 cm D: front: 10 cm Weight 13 kg dehumidifier TTK 71 E...
  • Page 18 Circuit diagram dehumidifier TTK 71 E...
  • Page 19 Condensor Cover-Right Evaporator Out-Evaporator Compressor Cover-Top Chassis Button Board Chassis Foot Cover Of Electric Box Main Body Main Board Motor Motor Capacitor Fan Blower Humidity Sensor Compressor Capacitor Electric Box Cover-Left Capillary Front Cover Working Tube dehumidifier TTK 71 E...