SECTION 3: INSTALLATION PROCEDURES
Aqua-Hot
Mounting
3.3

Mounting the Aqua-Hot

Once a mounting location for the Aqua-Hot has been selected, utilize the following
illustrations for mounting information:
- Overall Aqua-Hot Dimensions; reference Figure 5.
- Required size and locations of the Combustion-Air Hole and Exhaust
Holes; reference Figure 6.
- Required size and location of the Mounting Bracket Holes; reference
Figure 6.
- Minimum Heater clearances; reference the Aqua-Hot's Marking Plate
(Figure 3).
1.
Drill all the necessary holes prior to mounting the Aqua-Hot permanently into
place; reference Figure 6.
NOTES:
A.
Be sure to drill the holes for the Exhaust System and Combustion-Air
Intake prior to placing the Aqua-Hot into the permanent mounting
position.
B.
Be sure to utilize all four Mounting Brackets to ensure that the Aqua-Hot
does not move or shift under normal operating conditions.
2.
Place the Aqua-Hot into the permanent mounting position.
3.
Using 1/4 inch Bolts (total of eight required), fasten down the Aqua-Hot.
Aqua-Hot™ Hydronic Heating System Installation Manual 07/05