Aqua-Hot Reporter - Aqua-Hot 400 Series Service Manual

Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

Interlock Switch
Reporter

Aqua-Hot Reporter

Introduction:
The Aqua-Hot Reporter is a new generation of command
and control module which manages all functions of the Aqua-
Hot from start-up to shutdown. The previously used electronic
control board has been retired on new units in favor of the
Reporter.
Electrical Specifi cations:
The Reporter contains a single Amphenol ATP family
connector that serves as the power connection to the coach
side 12V DC power system. Mating connection components
are not supplied by Aqua-Hot. Compatible part numbers and
manufacturers are supplied below. The Reporter must be
operated to the below listed specifi cations.
Minimum Voltage.....................................11.0V DC
Maximum Voltage....................................15.0 V DC
Minimum Current.....................................75mA
Maximum Current....................................15A
Please note that the minimum current rating is the minimum
requirement for what will operate the Reporter. Operating
at this current rating will not provide suffi cient power to any
components dependent upon the Reporter.
Input Load currents
Zone Thermostats (each)..................................appx. 1mA
Diesel Burner Switch.........................................appx. 1mA
Electric Element Switch.....................................appx. 1mA
Low-Level Cutoff Switch.................................... appx. 1mA
Control Thermostat (Reporter 1.0)....................appx. 1mA
Tank Temperature Sensor (Reporter 2.0).........appx. 1mA
Low-Temperature Cutoff Thermostat................appx. 1mA
Output Load currents
Zone Fans (Reporter 1.0/all).................................3.0A max
Zone Fan 1 (Reporter 2.0).....................................8.0A max
Zone Fans 2-5 (Reporter 2.0)................................5.0A max
Zone Fans (all)......................................................0.25A max
Circulation Pumps (each).......................................2.0A max
AC Relay...................................................................0.5A max
Burner Power...........................................................6.0A max
Burner Master Control............................................2.0A max
Burner Thermostat Control....................................1.0A max
NOTE: For networked control of the Reporter, Aqua-Hot requires system integrators ensure that individual commands are
received and processed. Aqua-Hot requires that commands be repeated or confi rmed so that if a single message were dropped,
or if there is a brief network disturbance, the Reporter would get into the correct state as soon as the disruption was removed.
The Aqua-Hot Reporter monitors the heating system and handles all logic relating to safeties and heating control. As such, the
system integrator is required to display all pertinent status information but not use that information to lock out operation or add
additional safety layers that could impact the end of operation if a message from the Reporter was missed.
p. 30
Figure 61
©Aqua-Hot®
400P Service Manual
Connection Terminal Information
RV-C Mating Connection
Mfg.
Part Number
3M
37104-A165-OOE-MB
Reporter Power Connection
Deuthsche
Pins
1060-12-0222
Housing
DTP04-2P
Wedge
WP-2P
Harness Connections
Mfg.
Part Number
TE
1-480706-0
TE
1-480710-0
3M
37104-2165-000 FL
100
TE
1-480708-0
TE
1-480704-0
TE
640582-1
Sockets
Mfg.
Part Number
TE
350550-1
Socket Crimping Tool
Mfg.
Part Number
TE
90547-1
Description
RV-C Connection Housing
Amphenol
AT60-12-0222
ATP04-2P
AWP-2P
Description
Mate
09P UMNL Plug
J1
15P UMNL Plug
J2
CONN Plug 2MM 4POS
J3
20-22 AWG
12P UMNL Plug
J7
06P UMNL Plug
J8
08P UMNL Plug
J9
Description
Mate
J1
J2
J3
UMNL SOK 20-14
J7
TIN/PHBZ L/P
J8
J0
Description
ASSY Pro-Crimper M-N-L