Bosch VIP XD Installation And User Manual page 53

Bosch vip xd - network video server: installation and user guide
Table of Contents

Advertisement

EN | 53
VIP XD | Installation and User Guide
With the setting Follows alarm 1, the VIP XD automatically establishes a
connection to a remote station and maintains it for as long as an alarm signal is
present at alarm input 1. This option can also be used to connect two units
(transmitter and receiver) via a switch connected to the VIP XD. In this case, no
computer is needed to establish the connection.
Number of destination IP address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
Destination IP address:
For each number, enter the corresponding IP address for the desired remote
location.
Destination password:
If the remote location is password protected, enter the password here.
Auto-connect:
Select the option On if an active connection should be re-established
automatically to one of the previously specified IP addresses after each restart,
after a connection breakdown or network failure.
Relay
You can configure the switching behavior of the relay output. Open switch relay
(normally closed contact) or a closed switch relay (normally open contact) can
be specified.
It is also possible to specify whether the output should in a bistable or
monostable manner. In bistable operation, the activated state of the relay is
Bosch Security Systems | 2005-05 | V1.0
Configuration using a Web Browser

Advertisement

Table of Contents
loading

Table of Contents