SATURATED SUCTION PRESSURE
TEMPERATURE CHART
SUCTION PRESSURE
PSIG
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
85
90
95
100
110
120
130
140
150
160
170
d. If subcooling is high and superheat is low, adjust TXV
valve to 7 to 9 ºF superheat and remove charge to lower
the subcooling to 7 to 9ºF.
NOTE: Do NOT adjust the charge based on suction pressure
unless there is a gross undercharge.
Disconnect manifold set, installation is complete.
NOTE: Check the Schrader ports for leaks and tighten valve
cores if necessary. Install caps finger-tight.
SUBCOOL FORMULA =
SAT. LIQUID LINE TEMP. - LIQUID LINE TEMP.
SUPERHEAT FORMULA =
SUCT. LINE TEMP. - SAT. SUCT. TEMP.
SATURATED SUCTION
R-22
R-410A
26
1
28
3
29
4
31
6
32
7
34
8
35
10
37
11
38
13
40
14
41
15
42
16
44
17
45
19
46
20
48
21
50
24
53
26
56
29
59
31
64
36
69
41
73
45
78
49
83
53
86
56
90
60
SATURATED LIQUID PRESSURE
TEMPERATURE CH ART
LIQUID PRESSURE
PSIG
200
210
220
225
235
245
255
265
275
285
295
305
325
355
375
405
415
425
435
445
475
500
525
550
575
600
625
10. Supply Duct Connection
1. Top flanges can be bent for ease in installation to the
duct flanges. (See Figure 6)
5
SATURATED LIQUID
TEMPERATURE ºF
R-22
R-410A
101
70
105
73
108
76
110
78
113
80
116
83
119
85
121
88
124
90
127
92
130
95
133
97
137
101
144
108
148
112
155
118
157
119
n/a
121
n/a
123
n/a
125
n/a
130
n/a
134
n/a
138
n/a
142
n/a
145
n/a
149
n/a
152

Advertisement

Table of Contents
loading

This manual is also suitable for:

Downflow

Table of Contents