Download Print this page

F&F STR-4D Manual page 4

Roller blind controller for 12/24 v dc

Advertisement

�������-���� button can also close and lock the roller
blind in the closed position. If the �������-���� button
is pressed and left in the �� position, the controller will
close the roller blind and will not allow for its opening
until the �������-���� button is released (other inputs
will then be locked). This function allows you to lock the
roller blinds e.g. when the alarm is armed or when the
rainfall (if the additional STR-R rain sensor is used) or
too strong wind (if the additional STR-W wind sensor is
used) is detected.
Assembly
When preparing the installation powered with 12/24 V
voltage, it is necessary to provide a power source with
sufficient current capacity to supply all receivers. Too
small power supply may lead to improper operation of
motors and roller shutter controllers. Additionally, vol-
tage drops on cables (mainly power cables) should be
taken into account and, if necessary, the diameter of the
cables should be increased to reduce the voltage drop.
1. Disconnect the power supply.
2. Mount the controller on the rail in the distribution box.
3. Connect the controller accordingly to the selected scheme of
operation.
4. Switch on the power supply.
5. Program the time of lifting/lowering the roller blind.
- 4 -