Control
Controller control inputs are divided into two groups: local con-
trol and central control.
����� �������
Depending on how you connect the controller, it can operate in
one or two local buttons mode.
One local button
Local control input ���� is connected permanently to the "+"
(plus) line. Local control input �� is connected to a button that
alternately switches the roller blind to move up or down. Short
press (<0.5 s) switches on the blind for a programmed time.
Pressing the button when the roller blind is already in motion
causes the roller blind to stop. Long press (>0.5 s) switches on
the roller blind for as long as the button is pressed. Each time
you press the button the roller blind will move in the direction
opposite to the previous one.
Two local buttons
Each direction of movement has its own local button. Short press
(<0.5 s) switches on the roller blind to move in a given direction
for the programmed period of time. Pressing the button when
the roller blind is already in motion causes the roller blind to
stop.
Long press (>0.5 s) switches on the roller blind to move in a gi-
ven direction for as long as the button is pressed (this allows for
example to adjust the tilt of slats).