Unit Identifi Cation - Carrier 30PA Installation, Operation And Maintenance Instructions

Ductable air-cooled scroll chillers and heat pumps
Table of Contents

Advertisement

Ductable air-cooled scroll
chillers and heat pumps
5. T
ECHNICAL CHARACTERISTICS
Pump included
30PAC/PHC
Cooling
Seasonal effi ciency
Seasonal effi ciency
Average climate
Heating
Seasonal effi ciency
Warmer climate
Nominal water fl ow (m
Indoor circuit
Pressure drop (m.w.c.)
Volume (l)
Expansion
vessel
Filled pressure (kg/cm
30PAC/PHC
Cooling
Seasonal effi ciency
Seasonal effi ciency
Average climate
Heating
Seasonal effi ciency
Warmer climate
Nominal water fl ow (m
Indoor circuit
Pressure drop (m.w.c.)
Volume (l)
Expansion
vessel
Filled pressure (kg/cm
European Seasonal Energy Effi ciency Ratio (ESEER) obtained in accordance with the calculation conditions established by the certifi cation body EUROVENT.

Values
calculated in accordance with the
6. U
NIT IDENTIFICATION
Check the condition of the equipment upon delivery.
Check that the details on the label, the packing and the data plate match
the order. If equipment has been damaged, or there is a shortfall in
delivery, notify accordingly.
All units bear, legibly and indelibly, a data plate located in a prime space,
as appears in the attached image: Check that this plate matches the
correct model.
Año\An.Year
Ref\Reference
1
2
Producto\Product\Produit
Ref. Produit\Item Nbr
5
Tension\Voltage
Kit Elec.
8
Refrigerant
Refrig.KG (Fábrica\Factory\Usine)/Co2 Teq.
11
12
PSmax(AP\HP)
PSmax(BP\LP)
Temp. Max./ IP
13
14
CARRIER SCS
Fabricante\Fabricant\Manufacturer:
Route de Thil
Compañía Industrial de Aplicaciones Térmicas, S.A.
01122 Montluel-FRANCE
P. Ind. Llanos de Jarata s/n. 14550 Montilla-SPAIN
Contient des gaz à effet de serre fluorés \ Contains fluorinated greenhouse gases regulated by the Kyoto protocol
Contiene gases fluorados de efecto invernadero regulados por el protocolo de Kyoto
ESEER
SCOP
ŋs Heat
Prated (kW)
SCOP
ŋs Heat
Prated (kW)
/h)
3
)
2
ESEER
SCOP
ŋs Heat
Prated (kW)
SCOP
ŋs Heat
Prated (kW)
/h)
3
)
2
EN-14825-2013
standard given for
No Serie\serial Nbr.
3
4
6
7
Max.Intensidad\Intensité\Current
9
10
Peso\Poids\Weight
NoBo
15
16
90STD
100STD
2,67
2,61
3,24
3,13
126%
122%
16,83
19,20
3,82
3,60
150%
141%
12,77
14,71
3,1
3,7
3,1
4,2
90HEE
100HEE
2,95
3,00
3,12
2,95
122%
115%
15,75
17,51
3,64
3,56
143%
139%
13,12
14,69
3,2
3,7
2,3
3,1
bivalente temperature of -5ºC in average climate and 2ºC in warmer climate.
Legend
Year of manufacture
1
Commercial product name
2
Serial number
3
Description of the product
4
Purchase order number
5
Sales order number
6
Work order number
7
Power supply
8
Power output of the auxiliary electrical heaters kit (optional) (kW)
9
Maximum absorbed current under full load (A) ( including the electrical kit)
10
Type of refrigerant
11
Refrigerant content (kg) and Environment impact (CO
12
Maximum service pressure in the high pressure side (R-410A = 42 bar)
13
Maximum service pressure in the low pressure side (R-410A = 24 bar)
14
Maximum operating temperature (refer to "Opration limits")
15
Maximum shipment and storage temperature: +50ºC
Electrical protection rating: IP54
17
Operation weight (kg) (empty weight + fl uid + refrigerant)
16
Notifi ed Body number for surveillance of the Pressure Equipment Directive
17
Note: The serial number must be used in all correspondence
regarding the unit.
120STD
160STD
2,89
2,97
3,10
2,95
121%
115%
21,83
26,21
3,60
3,44
141%
135%
16,72
24,22
4,3
5,7
3,8
6,2
12
1,5
120HEE
160HEE
3,22
3,17
3,33
3,20
130%
125%
21,70
26,39
3,77
3,67
148%
144%
18,05
22,40
4,5
5,4
2,5
3,5
12
1,5
Teq.)
2
180STD
2,84
3,06
119%
30,53
3,57
140%
27,28
6,2
4,5
180HEE
3,02
3,08
120%
30,36
3,60
141%
25,83
6,2
4,6