Download Print this page

Panasonic HG-C Series Insruction Manual page 6

Micro laser distance sensor (cmos)

Advertisement

Procedure
Measurement display
DOWN: Press for 3 seconds
Response
time setting
High precision
UP /
TEACH
DOWN
UP / DOWN
Output operation
Light-ON
setting
UP /
TEACH
DOWN
UP / DOWN
Normal sensing
1-point teaching
Sensing output
mode
(Window comparator
mode)
setting
UP /
TEACH
DOWN
UP /
DOWN
UP /
DOWN
UP / DOWN
Trailing differential
Rising differential
mode
mode
Analog output
Analog voltage
Analog current
setting
output
output
UP /
TEACH
DOWN
UP / DOWN
Hysteresis setting
Hysteresis width
TEACH
UP key:
DOWN key:
UP / DOWN
Zero set function
Teaching function
External input setting
UP /
TEACH
DOWN
UP / DOWN
Timer setting
No timer
UP /
TEACH
DOWN
UP / DOWN
Display setting
Normal
UP /
TEACH
DOWN
UP / DOWN
Hold setting
Hold OFF
UP /
TEACH
DOWN
UP / DOWN
ECO setting
ECO OFF
UP /
TEACH
DOWN
UP / DOWN
Reset NG
Reset OK
Reset setting
UP /
TEACH
DOWN
UP / DOWN
Response
time setting
All manuals and user guides at all-guides.com
Standard
High speed
UP /
DOWN
Dark-ON
2-point teaching
(Window comparator
mode)
UP /
DOWN
UP /
DOWN
UP /
DOWN
3-point teaching
(Window
comparator mode)
Increases hysteresis width
Decreases hysteresis width
Light emitting stop
Trigger function
function
UP /
UP /
DOWN
DOWN
OFF-delay
ON-delay
One-shot
UP /
UP /
DOWN
DOWN
Invert
Offset
UP /
DOWN
Hold ON
ECO ON
13
Error indication
In case of error, attempt the following measures.
Error
Description
indication
Hold OFF
Insufficient amount of
- - - -
reflected light.
The sensing object
Hold ON
is out of the sensing
Measured
range.
value blinks
Flash memory is dam-
aged or passed its life
expectancy.
Load of the sensing
output is short-
circuited causing an
over-current to flow.
The semiconductor
laser is damaged or
passed its life expec-
tancy.
When zero set is set,
the measurement
is not performed
normally.
Since the display set-
ting is set to "Offset",
the zero set function
can not be used.
During teaching, the
measurement is not
performed normally.
System error
14
Cautions
● This product has been developed / produced for industrial use only.
● Make sure that the power supply is OFF before starting the wiring.
● If the wiring is performed incorrectly, it will cause a failure.
● Do not run the wires together with high-voltage lines or power lines,
or put them in the same raceway. This can cause malfunction due to
induction.
● Verify that the supply voltage variation is within the rating.
● If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is con-
nected to an actual ground.
● If noise generating devices (switching regulators, inverter motors,
etc.) are used around the sensor mounting area, make sure to con-
nect the frame ground (FG) terminal of the device.
● Do not use this product during the transient state when the power
supply is turned ON.
● The overall length of the cable can be extended to 10m maximum
with a cable size of max. 0.3mm
● Make sure that stress by forcible bend or pulling is not applied to the
sensor cable joint.
● Although it depends on the type, light from rapid start type or high
frequency lighting type, fluorescent lights, sunlight and etc. may affect
the sensing, therefore make sure to prevent direct incident light.
● This product is suitable for indoor use only.
● Keep water, oil, fingerprints and etc. which reflect light, dust or par-
ticles etc. which interrupt the light, away from the emitting / receiving
surfaces of this product. If contaminants adhere to the surface, wipe
off with a dust-free soft cloth, or lens cleaning paper.
● Do not use the sensor in locations where there is excessive vapor,
dust or etc. or in an atmosphere where corrosive gases, etc. are
generated.
● Take care that the product does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid or alkaline.
● Make sure to turn OFF the power supply, before cleaning the light
emitting / receiving windows of the sensor head.
6 6
Solution
Confirm that the sensing distance is within
the specification range.
Adjust the installation angle of the sensor.
Please contact our office.
Turn OFF the power and check the load.
Please contact our office.
Confirm that the sensing distance is within
the specification range.
Set the display to any setting except
"Offset.
Confirm that the sensing distance is within
the specification range.
Please contact our office.
.