Page 3
LADDER (8ft / 2.5m) ESTIMATED ASSEMBLY TIME: 8 HOURS IF YOU REQUIRE ASSISTANCE, OR NEED TO ORDER REPLACEMENT PARTS, CONTACT YOUR VISSCHER DEALER. KNIFE FOR ADDITIONAL INFORMATION PLEASE CALL THE NUMBER BELOW. PLEASE HAVE SERIAL NUMBER READY TO ENSURE QUICK SERVICE.
Page 5
HARDWARE NUEVA-COLORADO 11x14 1" #8 FLAT HEAD (#2 ROBERTSON) WITH SELF-DRILLING TIP ROBERTSON BIT 1" #8 PAN HEAD (#2 ROBERTSON) WITH SELF-DRILLING TIP 1 1/2" #8 FLAT HEAD (#2 ROBERTSON) 3/8" HEX HEAD BIT 264X 2 1/2" #8 FLAT HEAD (#2 ROBERTSON) 2 1/2"...
Page 7
STEP 1 NUEVA-COLORADO 11x14 USE FOAM GASKET (DC 1850) AND ADHERE TO PANEL EDGES CONNECTING TO POSTS (DC 2466) DC-2466 POST DC-1850 FOAM GASKET DC-2466 POST DC-1850 FOAM GASKET DC-1850 TRIM AS NEEDED DC-2499 PANEL DC-2420 PANEL TOLL FREE 1-877-795-7423...
STEP 2 NUEVA-COLORADO 11x14 ARRANGE TWO SETS OF PANELS (DC 2420, DC 2499) AND BACK POSTS (DC 2466) DC-2466 POST DC-2466 POST DC-2499 PANEL DC-2420 PANEL DC-2499 PANELS TOP VIEW DC-2499 PANEL DC-2420 PANEL DC-2499 PANELS TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 9
STEP 3 NUEVA-COLORADO 11x14 FASTEN THE PANELS TO THE POSTS (DC 2466). WALL PANELS ARE TO BE FLUSH WITH THE INSIDE EDGE OF THE POST AND FLUSH AT TOP AND BOTTOM. TOP VIEW DC-2466 POST DC-1850 FOAM GASKET DC-2466 POST...
Page 10
STEP 4 NUEVA-COLORADO 11x14 INSTALL FILLER STRIPS (DC 2069) AT PANEL JOINTS. FASTEN THE PANELS TOGETHER. WALL PANELS ARE TO BE FLUSH AT TOP AND BOTTOM. PANELS DC-2069 FILLER STRIP DC-2069 FILLER STRIP DC-2499 PANELS 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 11
STEP 5 NUEVA-COLORADO 11x14 USE FOAM GASKET (DC 1850) AND ADHERE TO PANEL EDGES CONNECTING TO THE FRONT LEFT POST (DC 2464). PREDRILLED PILOT HOLES MUST BE ORIENTED AS SHOWIN IN THE DIAGRAM. DC-2464 DC-2464 FRONT LEFT POST FRONT LEFT POST...
Page 12
STEP 6 NUEVA-COLORADO 11x14 FASTEN THE PANELS TO THE FRONT LEFT POST (DC 2464). NOTE THE ORIENTATION OF THE PREDRILLED PILOT HOLES FROM THE PREVIOUS STEP. WALL PANELS ARE TO BE FLUSH WITH THE INSIDE EDGE OF THE POST AND FLUSH AT BOTTOM.
Page 13
STEP 7 NUEVA-COLORADO 11x14 INSTALL FILLER STRIP (DC 2069) AT PANEL JOINT. WALL PANELS ARE TO BE FLUSH AT TOP AND BOTTOM. DC-2069 FILLER STRIP DC-2420 PANEL TOP VIEW DC-2420 PANEL 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423...
Page 14
STEP 8 NUEVA-COLORADO 11x14 INSTALL FILLER STRIP (DC 2069) AT PANEL JOINT. FASTEN THE TWO WALL ASSEMBLIES TOGETHER. WALL PANELS ARE TO BE FLUSH AT TOP AND BOTTOM. DC-2069 FILLER STRIP 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423...
Page 15
STEP 9 NUEVA-COLORADO 11x14 USE FOAM GASKET (DC 1850) AND ADHERE TO PANEL EDGES CONNECTING TO NARROW POSTS (DC 2487). FASTEN NARROW POSTS (DC 2487) TO REMAINING TWO PANEL EDGES, KEPT FLUSH ON THE INSIDE OF STRUCTURE. DC-2487 NARROW POSTS...
Page 16
STEP 10 NUEVA-COLORADO 11x14 ASSEMBLE THE FRONT-RIGHT POST ASSEMBLY. POSTS ARE TO BE FLUSH TO THE BOTTOM. PREDRILLED PILOT HOLES MUST BE ORIENTED AS SHOWIN IN THE DIAGRAM. DC-2490 FRONT RIGHT POST NOTE THE ORIENTATION OF THE PREDRILLED PILOT HOLES...
Page 17
STEP 11 NUEVA-COLORADO 11x14 FASTEN BACK BEAM (DC 2468) TO BACK PANELS, FLUSH TO INSIDE PANEL SURFACES, NOTCHES ON BEAM ORIENTED UPWARDS. BOTH ENDS OF THE BACK BEAM ARE TO ALIGN WITH THE INSIDE EDGES OF THE BACK POSTS. DC-2468 BACK BEAM...
Page 18
STEP 12 NUEVA-COLORADO 11x14 FASTEN SIDE BEAM (DC 2467) TO BACK BEAM AND LEFT POST. THE NOTCH LOCATED ON THE TOP OF THE BEAM IS TO BE ORIENTED CLOSER TO THE FRONT OF THE STRUCTURE. SCREWS SET DC-2467 SIDE BEAM 2"...
Page 19
STEP 13 NUEVA-COLORADO 11x14 FASTEN SIDE BEAM (DC 2467) TO SIDE PANELS, FLUSH TO INSIDE SURFACES OF PANELS. DC-2467 SIDE BEAM FLUSH FASTENED FROM OUTSIDE 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 20
STEP 14 NUEVA-COLORADO 11x14 FASTEN SIDE BEAM (DC 2467) TO BACK BEAM AND RIGHT POST. THE NOTCH LOCATED ON THE TOP OF THE BEAM IS TO BE ORIENTED CLOSER TO THE FRONT OF THE STRUCTURE. SCREWS SET DC-2467 SIDE BEAM 2"...
Page 21
STEP 15 NUEVA-COLORADO 11x14 FASTEN SIDE BEAM (DC 2467) TO SIDE PANEL, FLUSH TO INSIDE SURFACES OF WALL PANELS. DC-2467 SIDE BEAM FASTENED FROM OUTSIDE 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 22
STEP 16 NUEVA-COLORADO 11x14 FASTEN LOWER FRONT BEAM (DC 2468) TO FRONT POSTS. NOTCHES ORIENTED UPWARDS. DC-2468 LOWER FRONT BEAM 5-1/8" X 5/16" RSS (T30 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 23
STEP 17 NUEVA-COLORADO 11x14 FASTEN LOWER FRONT BEAM (DC 2468) TO FRONT PANEL, FLUSH TO INSIDE SURFACES OF WALL PANELS. DC-2468 LOWER FRONT BEAM FASTENED FROM OUTSIDE 2 1/2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 24
STEP 18 NUEVA-COLORADO 11x14 FIT THE TWO THRESHOLD PIECES (DC 2485, 2486) BETWEEN POSTS AND FLAT ON THE FLOOR. FASTEN THRESHOLDS TO THE POSTS. TOP VIEW DC-2486 SHORT THRESHOLD FLUSH DC-2485 LONG THRESHOLD RIGHT POST ASSEMBLY FLUSH RIGHT POST ASSEMBLY...
Page 25
STEP 19 NUEVA-COLORADO 11x14 FASTEN FRONT MIDDLE UPRIGHTS (DC 2471, 24-3/8" LONG) TO LOWER FRONT BEAM. ALIGN UPRIGHTS WITH NOTCHES FOUND ON BEAM. DC 2471 FRONT MIDDLE UPRIGHT NOTCH ON BEAM 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423...
Page 26
STEP 20 NUEVA-COLORADO 11x14 FASTEN FRONT END UPRIGHTS (DC 2470, 24-3/8" LONG) TO LOWER FRONT BEAM. ALIGN UPRIGHTS WITH NOTCHES FOUND ON BEAM. DC-2470 FRONT END UPRIGHT NOTCH ON BEAM 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 27
STEP 21 NUEVA-COLORADO 11x14 FASTEN SIDE END UPRIGHTS (DC 2472, 29-9/16" LONG) TO FRONT POSTS. ALIGN UPRIGHTS WITH NOTCHES FOUND ON BEAMS. DC-2472 SIDE END UPRIGHT NOTCH ON BEAM 5-1/8" X 5/16" RSS (T30 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 28
STEP 22 NUEVA-COLORADO 11x14 FASTEN SIDE MIDDLE UPRIGHTS (DC 2473, 19-3/4" LONG) TO SIDE BEAMS. ALIGN UPRIGHTS WITH NOTCHES FOUND ON BEAMS. DC-2473 SIDE MIDDLE UPRIGHT NOTCH ON BEAM 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 29
STEP 23 NUEVA-COLORADO 11x14 FIT FRONT WINDOWS (DC 2581, 2582). FASTEN TO BEAM AND UPRIGHTS AT BOTTOM SCREW HOLE LOCATIONS ONLY. DC-2582 WINDOW DC-2581 WINDOW DC-2581 WINDOW DC-2582 WINDOW BOTTOM SCREW HOLE LOCATIONS ONLY 1" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 30
STEP 24 NUEVA-COLORADO 11x14 FASTEN UPPER FRONT BEAM (DC 2468) TO POSTS. FIT UPRIGHTS INTO NOTCHES ON BEAM. DC-2468 UPPER FRONT BEAM UPRIGHTS INTO NOTCHES ON BEAM 5-1/8" X 5/16" RSS (T30 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 31
STEP 25 NUEVA-COLORADO 11x14 FASTEN THE FRONT UPRIGHTS TO THE UPPER FRONT BEAM. 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 32
STEP 26 NUEVA-COLORADO 11x14 FASTEN FRONT WINDOWS (DC 2581, 2582) TO BEAM AND UPRIGHTS AT TOP SCREW HOLE LOCATIONS. 1" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 33
STEP 27 NUEVA-COLORADO 11x14 FIT TWO GUSSET COMPONENTS (DC 2495, 2496) TO MAKE A GUSSET ASSEMBLY. FASTEN TOGETHER WITH ONE SCREW THROUGH THE TOP FACE. DRIVE THE SCREW DEEP ENOUGH SO THE SCREW HEAD IS BURIED ENTIRELY. PRODUCE TWO GUSSET ASSEMBLIES.
Page 34
STEP 28 NUEVA-COLORADO 11x14 FASTEN GUSSET COMPONENTS FURTHER BY ADDING TWO SCREWS THAT WILL FACE THE INSIDE OF THE STRUCTURE. SEE NEXT STEP FOR A VISUAL. SERIAL NUMBER TAG SHOULD ALSO FACE THE INSIDE OF THE STRUCTURE WHEN ASSEMBLED. PRODUCE TWO GUSSET ASSEMBLIES.
Page 35
STEP 29 NUEVA-COLORADO 11x14 FIT THE SIDE WINDOWS (DC 2583, 2584, 2585, 2586) AND GUSSET ASSEMBLIES. FASTEN TO BEAM AND UPRIGHTS AT SCREW LOCATIONS IDENTIFIED IN DIAGRAM ONLY. DO NOT FASTEN GUSSET ASSEMBLIES TO THE STRUCTURE AT THIS TIME. DC-2585 WINDOW...
Page 36
STEP 30 NUEVA-COLORADO 11x14 FIT AN END RAFTERS (DC 2475) AND FASTEN TO THE SIDE MIDDLE UPRIGHT. ADJUST THE LOCATION OF THE GUSSET ASSEMBLY AS NECESSARY FOR THE RAFTER TO SIT TIGHT TO BEAM AND UPRIGHTS. REPEAT THIS STEP FOR BOTH END RAFTERS.
Page 37
STEP 31 NUEVA-COLORADO 11x14 FASTEN THE END RAFTER TO THE POSTS. USE THE BIT EXTENSION TO REACH FULL DEPTH. REPEAT THIS STEP FOR BOTH END RAFTERS. BIT EXTENSION 5-1/8" X 5/16" RSS (T30 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 38
STEP 32 NUEVA-COLORADO 11x14 ADJUST THE GUSSET UNTIL IT IS TIGHT TO THE BEAM AND END RAFTER. FASTEN TO THE BEAM AND RAFTER FROM THE INSIDE OF THE STRUCTURE. GUSSET TIGHT TO RAFTER GUSSET TIGHT TO BEAM 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 39
STEP 33 NUEVA-COLORADO 11x14 FASTEN SIDE WINDOWS TO UPRIGHTS, RAFTER AND GUSSET AT SCREW HOLE LOCATIONS SHOWN ON DIAGRAM. REPEAT THIS STEP FOR ALL FOUR SIDE WINDOWS. 1" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 40
STEP 34 NUEVA-COLORADO 11x14 FIT MIDDLE RAFTER ASSEMBLY COMPONENTS (DC 2474, 2475, 2478). THREE MIDDLE RAFTER ASSEMBLIES WILL BE PRODUCED. DC-2478 SPUR UPRIGHT DC-2475 RAFTER FLUSH DC-2474 ANGLE BRACE ANGLE BRACE FIT TIGHT TO RAFTER TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 42
STEP 36 NUEVA-COLORADO 11x14 FIT ONE OUTSIDE UPPER FILLER (DC 2480 38-9/16") TO UPPER BEAM. FIT ONE OUTSIDE LOWER FILLER (DC 2483 38-9/16") TO LOWER BEAM. DO NOT FASTEN TO BEAMS AT THIS TIME. DC-2480 38-9/16" OUTSIDE UPPER FILLER DC-2483 38-9/16"...
Page 43
STEP 37 NUEVA-COLORADO 11x14 FIT THREE RAFTER ASSEMBLIES ON TOP BEAMS, SPACED EVENLY BY UPPER FILLERS (DC 2481, 2482) AND LOWER FILLERS (DC 2483, 2484). RAFTER WILL SIT IN NOTCHES FOUND IN BACK BEAMS DO NOT FASTEN TO THE STRUCTURE AT THIS TIME.
Page 44
STEP 38 NUEVA-COLORADO 11x14 FASTEN FILLERS TO FRONT AND BACK BEAMS. FRONT BEAM BACK BEAM 2" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 45
STEP 39 NUEVA-COLORADO 11x14 FIT THE TIE BEAMS (DC 2479) TIGHT TO THE RAFTER ASSEMBLIES AND BENEATH THE SPUR UPRIGHTS. TIE BEAMS ARE TO REST ON THE NOTCHED PORTION. THE CUT IS ORIENTED TO THE BACK OF THE STRUCTURE. DO NOT FASTEN TIE BEAMS TO THE STRUCTURE AT THIS TIME.
Page 46
STEP 40 NUEVA-COLORADO 11x14 FASTEN RAFTER ASSEMBLIES TO FRONT AND BACK BEAMS. USE THE BIT EXTENSION TO REACH FULL DEPTH. BIT EXTENSION 5-1/8" X 5/16" RSS (T30 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 47
STEP 41 NUEVA-COLORADO 11x14 FASTEN THE TIE BEAMS TO THE RAFTER ASSEMBLIES AND MIDDLE FRONT UPRIGHTS. SCREWS CENTRED ON SPUR UPRIGHT 2 3/4" #10 RSS (T25 TORX) TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
STEP 42 NUEVA-COLORADO 11x14 FIT THE TWO STARTER CEILING BOARDS (DC 2507) ON THE RAFTERS AND FLUSH TO THE BOTTOM EDGES OF THE RAFTERS, TONGUE FACING UPWARDS. CEILING BOARDS TO TOUCH AT THE CENTRE OF THE MIDDLE RAFTER. FASTEN TO EACH RAFTER AS SHOWN IN DIAGRAM.
Page 49
STEP 43 NUEVA-COLORADO 11x14 FIT TWO FULL CEILING BOARDS (DC 2500), GROOVE-TO-TONGUE WITH THE STARTER CEILING BOARDS. CEILING BOARDS TO TOUCH AT THE CENTRE OF THE MIDDLE RAFTER. FASTEN TO EACH RAFTER AS SHOWN IN DIAGRAM. DC-2500 FULL CEILING BOARD...
Page 50
STEP 44 NUEVA-COLORADO 11x14 FIT THE REMAINING FULL CEILING BOARDS (DC 2500), FASTENING EACH ROW FULLY BEFORE MOVING TO THE NEXT. CEILING BOARDS TO TOUCH AT THE CENTRE OF THE MIDDLE RAFTER, TIGHT TO EACH END. FASTEN TO EACH RAFTER AS SHOWN IN DIAGRAM.
Page 51
STEP 45 NUEVA-COLORADO 11x14 ROLL TAR PAPER (DC 2436) FLAT ACROSS CEILING BOARDS, TIGHT TO THE BOTTOM MOST EDGE OF THE CEILING. STAPLE THE FIRST ROW OF TAR PAPER TO THE CEILING BOARDS USING 1/2" STAPLES, SPACED A MAXIMUM OF 12" APART FROM EACH OTHER.
Page 52
STEP 46 NUEVA-COLORADO 11x14 ROLL FOUR MORE ROWS OF TAR PAPER (DC 2436) FLAT ACROSS CEILING BOARDS, OVERLAPPING EACH PREVIOUS ROW BY 6 INCHES. STAPLE TO THE CEILING BOARDS USING 1/2" STAPLES, SPACED A MAXIMUM OF 12" APART FROM EACH OTHER.
Page 53
STEP 47 NUEVA-COLORADO 11x14 FIT AN UNDERSIDE FLASHING PIECE (DC 2673) ON THE BOTTOM EDGE OF THE ROOF ASSEMBLY, TIGHT TO THE END OF THE CEILING BOARD. REVIEW THE ORIENTATION OF TABS FOUND ON THE FIRST ROOF SHEET (DC 2493) IN THE DIAGRAM BELOW.
Page 54
STEP 48 NUEVA-COLORADO 11x14 ALIGN THE FIRST ROOF SHEET, FOAM CLOSURE AND UNDERSIDE FLASHING TO THE EDGES OF THE CEILING BOARD. FASTEN THROUGH THE PRE-PUNCHED HOLE LOCATIONS, AND THROUGH THE UNDERSIDE FLASHING. CONTINUE LAYING FOAM CLOSURES, ROOF SHEETS AND UNDERSIDE FLASHING TO COMPLETE THE FIRST ROW OF ROOFING.
Page 55
STEP 49 NUEVA-COLORADO 11x14 ALIGN THE NEXT ROW OF ROOF SHEETS AND FOAM CLOSURES TO THE EDGES OF THE CEILING BOARD. FASTEN THROUGH THE PRE-PUNCHED HOLE LOCATIONS, AND THROUGH THE UNDERLAPPED ROOF SHEET. CONTINUE LAYING FOAM CLOSURES AND ROOF SHEETS TO COMPLETE THE LAST ROW OF ROOFING.
Page 56
STEP 50 NUEVA-COLORADO 11x14 FIT THE SHORT SIDE FLASHING SO IT REACHES THE BOTTOM EDGEOF THE BOTTOM ROOF SHEET, AND FASTEN WITH TWO SCREWS ONLY AT LOCATIONS SHOWN IN DIAGRAM, 13 INCHES APART. FIT THE LONG SIDE FLASHING (DC 2671) OVER THE SHORT PORTION, AND HAVE IT REACH THE TOP EDGE OF THE TOP ROOF SHEET. FASTEN WITH FIVE SCREWS THROUGH TOP RIB, 24 INCHES APART.
Page 57
STEP 51 NUEVA-COLORADO 11x14 FIT THE TOP FLASHING (DC 2670) SO THAT IT OVERLAPS THE SIDE FLASHINGS. FASTEN TO THE ROOF METAL THROUGH EVERY SECOND RIB. FASTEN THROUGH EVERY SECOND DC-2670 TOP FLASHING 3/4" #14 HEX TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 58
STEP 52 NUEVA-COLORADO 11x14 FIT STRIKE POST (DC 2488) TO FRONT RIGHT POST ASSEMBLY. STRIKE POST TO SIT TIGHT TO FLOOR. FOLLOW THE CRITICAL DIMENSION ON THE DIAGRAM BELOW BEFORE FASTENING. USE PRE-DRILLED PILOT HOLES TO SET THE LOCATIONS OF THE FASTENERS.
Page 59
STEP 53 NUEVA-COLORADO 11x14 FIT THE THREE-DOOR BOTTOM TRACK (DC-2594) TO THE THRESHOLD AND TIGHT TO THE STRIKE POST. FASTEN THROUGH THE PRE-DRILLED HOLES. DC-2594 THREE-DOOR BOTTOM TRACK FIT TIGHTLY TO STRIKE POST 1" #8 PAN HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423...
Page 60
STEP 54 NUEVA-COLORADO 11x14 FIT THE SHORT BOTTOM TRACK (DC 2602) TO THE THRESHOLD, POST AND TIGHT TO THE ADJACENT TRACK. PUSH WALL PANEL INWARDS OR OUTWARDS TO ENSURE TRACK ARE IN-LINE WITH EACH OTHER. TRACKS TO BE IN-LINE WITH EACH OTHER...
Page 61
STEP 55 NUEVA-COLORADO 11x14 FIT THE WEATHERSTRIP, EDGE FLUSH TO THE NARROW POST AND FIT TIGHTLY TO THE BOTTOM TRACK. FASTEN TO THE NARROW POST THROUGH PRE-DRILLED HOLES. DC-2609 WEATHERSTRIP EDGE FLUSH TO FACE OF NARROW POST TIGHT TO BOTTOM TRACK 1"...
Page 62
STEP 56 NUEVA-COLORADO 11x14 FIT THE LONG TOP TRACK (DC 2593) TO THE FRONT BEAM, RESTING ON THE WEATHERSTRIP AND STRIKE POST. ALIGN THE TOP TRACK TO THE INSIDE EDGE OF THE POSTS. DC-2593 LONG TOP TRACK EDGE OF TOP TRACK...
Page 63
STEP 57 NUEVA-COLORADO 11x14 TO FACILITATE THE INSTALLATION OF THE DOOR SYSTEM, REMOVE THE SHORT BOTTOM TRACK AND THE END CAP OF THE TOP TRACK. CAREFULLY MANEUVER THE DOOR SYSTEM SO THE TOP ROLLERS ARE IN-LINE WITH THE TOP TRACK.
Page 64
STEP 58 NUEVA-COLORADO 11x14 CAREFULLY LIFT THE DOOR SYSTEM UP AND MOVE THE TOP ROLLERS INTO THE TOP TRACK. ALIGN THE BOTTOM PINS SO THEY ENTER THE CHANNEL IN THE BOTTOM TRACK. TOP TRACK TOP ROLLERS BOTTOM PINS BOTTOM TRACK TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 65
STEP 59 NUEVA-COLORADO 11x14 THE DOOR SYSTEM IS EXTREMELY HEAVY. THE DOOR SYSTEM IS PRONE TO ROLLING OUT USE CAUTION WHEN LIFTING AND MANEUVERING OF THE TRACK IF NOT MONITORED, RESULTING IN THE PRODUCT. DAMAGE TO PROPERTY OR PERSONAL INJURY.
Page 66
STEP 60 NUEVA-COLORADO 11x14 RE-INSTALL THE SHORT BOTTOM TRACK AND TOP TRACK END CAP. TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 67
STEP 61 NUEVA-COLORADO 11x14 ALIGN THE STRIKE PLATE (DC 2577) SO THE STRIKE AND DEADBOLT BOTH ALIGN WITH THE HOLES. FASTEN STRIKE PLATE TO THE STRIKE POST. STRIKE POST DC-2577 STRIKE PLATE 1 1/2" #8 FLAT HEAD (#2 ROBERTSON) TOLL FREE 1-877-795-7423...
Page 68
STEP 62 NUEVA-COLORADO 11x14 MEASURE 40 INCHES FROM THE FLOOR TO SET THE HANDLE (DC 2605) TO THE METAL FRAME OF THE DOOR. TWO TABS ON THE HANDLE ARE TO FIT TIGHTLY TO INSIDE OF METAL FRAME OF THE DOOR.
Page 69
STEP 63 NUEVA-COLORADO 11x14 TO DETERMINE THE PLACEMENT OF THE KEEPER, ASSEMBLE THE HANDLE, PIN AND KEEPER (DC 2604) TOGETHER. PULL THE HANDLE INWARDS AND TIGHT TOWARDS THE POST. MARK THE EDGES OF THE KEEPER ON THE POST WITH A PENCIL.
Page 70
STEP 64 NUEVA-COLORADO 11x14 FIT THE TWO-DOOR BOTTOM TRACK (DC-2601) TO THE THRESHOLD AND PAST THE POST BY 3/8 INCH. FIT THE SHORT BOTTOM TRACK (DC 2602) TO THE THRESHOLD, POST AND TIGHT TO THE ADJACENT TRACK. PUSH WALL PANEL INWARDS OR OUTWARDS TO ENSURE TRACK ARE IN-LINE WITH EACH OTHER.
Page 71
STEP 65 NUEVA-COLORADO 11x14 FIT THE WEATHERSTRIP, EDGE FLUSH TO THE POST AND FIT TIGHTLY TO THE BOTTOM TRACK. FASTEN TO THE POSTS THROUGH PRE-DRILLED HOLES. DC-2609 WEATHERSTRIP EDGE FLUSH TO FACE EDGE FLUSH TO FACE OF POST OF POST...
Page 72
STEP 66 NUEVA-COLORADO 11x14 FIT THE SHORT TOP TRACK (DC 2600) TO THE SIDE BEAM, RESTING ON BOTH WEATHERSTRIP COMPONENTS. ALIGN THE TOP TRACK TO THE INSIDE EDGES OF THE POSTS. DC-2600 SHORT TOP TRACK EDGE OF TOP TRACK TO INSIDE EDGE...
Page 73
STEP 67 NUEVA-COLORADO 11x14 TO FACILITATE THE INSTALLATION OF THE DOOR SYSTEM, REMOVE THE SHORT BOTTOM TRACK AND THE END CAP OF THE TOP TRACK. CAREFULLY MANEUVER THE DOOR SYSTEM SO THE TOP ROLLERS ARE IN-LINE WITH THE TOP TRACK.
Page 74
STEP 68 NUEVA-COLORADO 11x14 CAREFULLY LIFT THE DOOR SYSTEM UP AND MOVE THE TOP ROLLERS INTO THE TOP TRACK. ALIGN THE BOTTOM PINS SO THEY ENTER THE CHANNEL IN THE BOTTOM TRACK TOP TRACK TOP ROLLERS BOTTOM TRACK BOTTOM PINS TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 75
STEP 69 NUEVA-COLORADO 11x14 THE DOOR SYSTEM IS EXTREMELY HEAVY. THE DOOR SYSTEM IS PRONE TO ROLLING OUT USE CAUTION WHEN LIFTING AND MANEUVERING OF THE TRACK IF NOT MONITORED, RESULTING IN THE PRODUCT. DAMAGE TO PROPERTY OR PERSONAL INJURY.
Page 76
STEP 70 NUEVA-COLORADO 11x14 RE-INSTALL THE SHORT BOTTOM TRACK AND TOP TRACK END CAP. TOLL FREE 1-877-795-7423 0137_Nueva-Colorado_Instructions_V1.1...
Page 77
STEP 71 NUEVA-COLORADO 11x14 MEASURE 40 INCHES FROM THE FLOOR TO SET THE HANDLE (DC 2605) TO THE METAL FRAME OF THE DOOR. TWO TABS ON THE HANDLE ARE TO FIT TIGHTLY TO INSIDE OF METAL FRAME OF THE DOOR.
Page 78
STEP 72 NUEVA-COLORADO 11x14 THE TWO DOOR SYSTEM WILL REST UN-LEVEL. TO LEVEL, LIFT UPWARDS ON THE HANDLE WHEN LOCATING THE PLACEMENT OF THE KEEPER. ASSEMBLE THE HANDLE, PIN AND KEEPER (DC 2604) TOGETHER. PULL THE HANDLE INWARDS, UPWARDS AND TIGHT TOWARDS THE POST. MARK THE EDGES OF THE KEEPER ON THE POST WITH A PENCIL.
Page 79
STEP 73 NUEVA-COLORADO 11x14 FOLD THE TWO-DOOR SYSTEM AND MOVE IN FRONT OF THE WALL PANEL MOUNT A KEEPER (DC 2604) ON THE BACK POST AT THE SAME HEIGHT AS THE HANDLE. HANDLE DC-2604 PIN AND KEEPER BACK POST HANDLE...
STEP 74 NUEVA-COLORADO 11x14 MOUNT A MAGNET ASSEMBLY TO THE SWINGING DOOR PANEL AT THE LOCATION SHOWN IN THE DIAGRAM. DO NOT MOUNT THE RECEIVER ASSEMBLY UNTIL THE MAGNET ASSEMBLY STEP IS COMPLETE. 1" FROM EDGE TO CENTRE MAGNET ASSEMBLY...
STEP 75 NUEVA-COLORADO 11x14 FOLD THE DOOR SYSTEM TO DETERMINE THE LOCATION OF THE RECEIVER ASSEMBLY. USING A PENCIL, MARK THE LOCATION THE MAGNET ASSEMBLY AS IT APPROACHES THE METAL FRAME. FASTEN THE RECEIVER ASSEMBLY TO THE METAL FRAME AT THAT LOCATION.
Page 82
STEP 76 NUEVA-COLORADO 11x14 MOUNT A MAGNET ASSEMBLY TO THE SWINGING DOOR PANEL AT THE LOCATION SHOWN IN THE DIAGRAM. DO NOT MOUNT THE RECEIVER ASSEMBLY UNTIL THE MAGNET ASSEMBLY STEP IS COMPLETE. MAGNET ASSEMBLY 1" FROM EDGE TO CENTRE...
Page 83
STEP 77 NUEVA-COLORADO 11x14 FOLD THE DOOR SYSTEM TO DETERMINE THE LOCATION OF THE RECEIVER ASSEMBLY. USING A PENCIL, MARK THE LOCATION THE MAGNET ASSEMBLY AS IT APPROACHES THE METAL FRAME. FASTEN THE RECEIVER ASSEMBLY TO THE METAL FRAME AT THAT LOCATION.
Need help?
Do you have a question about the NUEVA-COLORADO 11x14 and is the answer not in the manual?
Questions and answers