Cutting Unit Operating Problems

Problem
Engine Continues to run (but should not) when the
cutting unit switch is ON with no operator in the seat.
Cutting units run (but should not) when raised.
However, they shut off with the cutting unit switch
Cutting units shut off when raised. However, they do
not shut off with the cutting unit switch.
Cutting units do not engage.
Reelmaster 2300–D/2600–D
Possible Causes
Backlap switch is in the backlap position.
Backlap switch is faulty or out of adjustment.
Wiring to the run/mow/backlap circuits (see Wiring
Schematics) components is loose, corroded, or
damaged.
Seat switch is faulty, out of adjustment, or short
circuited.
Cutting unit interlock switch is faulty.
Cutting unit switch is faulty or short circuited.
Wiring to run/mow/backlap circuits (see Wiring
Schematics) components is loose, corroded, or
damaged.
ACC fuse (10 amp) is open.
Fuse block is faulty.
Cutting units are not lowered.
Cutting unit switch is faulty.
Cutting unit interlock switch is faulty.
Cutting solenoid valve is faulty.
Page 5 – 13
Electrical System