Cutting Unit Operating Problems

Cutting units run, but should not, when raised. Cutting
units shut off with PTO switch.
Cutting units run, but should not, when raised. Cutting
units do not shut off with the PTO switch.
Cutting units run, but should not, when lowered with
PTO switch in the OFF (disengage) position.
Cutting unit(s) do not operate.
Cutting unit(s) operation is intermittent over rough
terrain.
Electrical System
The cutting unit position switch or circuit wiring is
faulty.
Wire harness connections are incorrectly connected to
hydraulic solenoid valve coils on hydraulic mow control
manifold.
The cutting unit position switch or circuit wiring AND
PTO switch or circuit wiring are faulty.
A hydraulic problem exists (see Troubleshooting
Section of Chapter 4 -- Hydraulic System).
The PTO switch or circuit wiring is faulty.
The cutting units are not fully lowered.
The operator seat is unoccupied.
Mow speed limiter is not in mow position (4WD).
The PTO switch or circuit wiring is faulty.
The cutting unit position switch or circuit wiring to the
affected cutting unit(s) is faulty.
Hydraulic solenoid valve coil(s) or circuit wiring to the
affected cutting units is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 -- Hydraulic System).
The cutting unit lift/lower switch or circuit wiring is
faulty.
Page 5 - - 12
Reelmaster 7000